Loading…
Name ID Label Description Type Access Class
abs_vol_flow_total_USL 4110 USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
dev_electronics_temp_DampingValue 411C Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 0
dev_electronics_temp_PDQ 4117 PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
dev_electronics_temp_Status 41FD Family status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2051
dev_electronics_temp_Units 4116 Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R Enum 0
dev_electronics_temp_Value 40AC Temperature of REM electronics Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 2
dev_electronics_temp_LS 4118 LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
dev_electronics_temp_LSL 411A LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
dev_electronics_temp_MinimumSpan 411B Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
dev_electronics_temp_Precision 411E Format A display format specifies how a host application must display the value. R Enum 2048
Name ID Label Description Type Access Class