Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
Relative_Humidity_Simulated | 402A | Simulate | W | Enum | 2052 | |
Relative_Humidity_UpdatePeriod | 402B | Temp Update Period | R | Time | 0 | |
MEASUREMENT_CHANNEL_INDEX | 402D | Measurement Channel Index | Measurement Channel Index | R/W | Enum | 4096 |
MEASUREMENT_MODE_VALUE | 402E | Measurement Mode Value | Contains the currently measured gas concentration | R | Float | 0 |
MEASUREMENT_MODE_DECIMAL_ADJUST | 402F | Decimal Adjust | Number of decimal places for the target gas concentration on the display | R | Enum | 10 |
TX_STATE | 4030 | TX State | TX State | R | BitEnum | 10 |
MEASUREMENT_MODE_ALARM_CONDITION | 4031 | Alarm Condition | Contains information whether the A1 or A2 alarm is activated and whether the current measured value is above or below the alarm condition. | R | BitEnum | 10 |
DEVICE_STATUS_INDICATION | 4032 | Device Status Indication | Contains information on the current status of the gas detector. Warnings and/or errors are displayed as group warnings and group errors. | R | BitEnum | 10 |
DEVICE_STATUS_VALUE01 | 4033 | Device Status Value01 | The parameter contains detailed information on the current status of the gas detector as a warning matrix. | R | BitEnum | 10 |
DEVICE_STATUS_VALUE02 | 4034 | Device Status Value02 | The parameter contains detailed information on the current status of the gas detector as an error matrix. | R | BitEnum | 10 |
Name | ID | Label | Description | Type | Access | Class |