Loading…
Name ID Label Description Type Access Class
Relative_Humidity_Simulated 402A Simulate W Enum 2052
Relative_Humidity_UpdatePeriod 402B Temp Update Period R Time 0
MEASUREMENT_CHANNEL_INDEX 402D Measurement Channel Index Measurement Channel Index R/W Enum 4096
MEASUREMENT_MODE_VALUE 402E Measurement Mode Value Contains the currently measured gas concentration R Float 0
MEASUREMENT_MODE_DECIMAL_ADJUST 402F Decimal Adjust Number of decimal places for the target gas concentration on the display R Enum 10
TX_STATE 4030 TX State TX State R BitEnum 10
MEASUREMENT_MODE_ALARM_CONDITION 4031 Alarm Condition Contains information whether the A1 or A2 alarm is activated and whether the current measured value is above or below the alarm condition. R BitEnum 10
DEVICE_STATUS_INDICATION 4032 Device Status Indication Contains information on the current status of the gas detector. Warnings and/or errors are displayed as group warnings and group errors. R BitEnum 10
DEVICE_STATUS_VALUE01 4033 Device Status Value01 The parameter contains detailed information on the current status of the gas detector as a warning matrix. R BitEnum 10
DEVICE_STATUS_VALUE02 4034 Device Status Value02 The parameter contains detailed information on the current status of the gas detector as an error matrix. R BitEnum 10
Name ID Label Description Type Access Class