Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
dec_sensor_value | 4000 | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 10 |
dec_sensor_units | 4001 | PV Snsr unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
dec_sensor_upper_limit | 4002 | PV USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
dec_sensor_lower_limit | 4003 | PV LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
dec_sensor_minimum_span | 4004 | PV Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
dec_sensor_damping_value | 4005 | PV Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 8 |
dec_analog_value | 4006 | AO1 | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes | R/W | Float | 66 |
dec_analog_alarm_code | 4007 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
dec_calibration_date | 4008 | CalDate | The user is encouraged to keep track of the last calibration date here. This date is for information only and is not used in any internal calculations. | R/W | HartDate | 12 |
dec_input_percent_range | 4009 | PV % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
dec_input_transfer_function | 400A | Xfer fnctn | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. | R | Enum | 32 |
dec_input_upper_value | 400B | PV URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R | Float | 32 |
dec_input_lower_value | 400C | PV LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R | Float | 32 |
dec_sensor_serial_number | 400D | PV Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
dec_log_request | 400E | Event log request | W | Enum | 4096 | |
dec_password | 400F | Set Password | The password is used to validate the command to enable or disable writes in the device. | W | ASCII | 2052 |
dec_write_enable | 4010 | Set Write Protect | Used to set the write protect mode. With Write Protect (On), variables cannot be written to the device and commands that cause actions to be performed in the device cannot occur. | W | Enum | 2052 |
x3302_bit_fire_status | 401F | Fire | Indicates (Y) if the device is in a fire alarm status. - analog output is at 20mA, fire alarm relay is actuated and LED is red. | R | Enum | 2051 |
x3302_bit_oi_cal_active | 4020 | Oi Calibrate Active | Oi Calibration is active. | R | Enum | 2051 |
x3302_bit_man_oi_active | 4021 | Manual Oi Active | Manual Oi is active. | R | Enum | 2051 |
x3302_bit_warm_up | 4022 | Warm Up | Device is in the power-up time delay (warm-up) mode. Normal duration 30 seconds. | R | Enum | 2051 |
x3302_bit_fault_status | 4023 | Fault | Indicates (Y) if a fault condition exists.Go to (Device Info) and select (Status Info) to determine the nature of the fault. | R | Enum | 2051 |
x3302_bit_auto_oi_fault | 4024 | Automatic Oi Fault | Automatic Oi Fault. Check viewing windows and Oi reflector plate for cleanliness. | R | Enum | 2051 |
x3302_bit_man_oi_fault | 4025 | Manual Oi Fault | The detector has failed the last manual Oi test. | R | Enum | 2051 |
x3302_bit_oi_cal_fault | 4026 | Oi Calibrate Fault | An Oi calibration fault has occured. | R | Enum | 2051 |
Name | ID | Label | Description | Type | Access | Class |