Loading…
Name ID Label Description Type Access Class
reference_normalized 4032 Reference normalized R Unsigned 258
Control_word 4033 Control word to start calibration,alignmet etc R Unsigned 2048
detector_gain 4034 Gain Amplifier step value to boost the signal R Enum 10
interconnect_mode 4035 Interconnect mode Detector Setting for stand alone or Interconnect mode R/W Enum 8
InterimBeamBlockFault_Settings 4036 Log Interim beam block fault Settings to log the interim beam block fault R/W Enum 8
readbackfault_setting 4037 Read back fault settings On/Off the 4-20 output loop fault monitoring R/W Enum 8
eLOOP_CURRENT_FAULT_MODE 4038 Output fault mode Set the 4-20 output fault current modes R/W Enum 8
eLOOP_CURRENT_NO_DETECT_LEVEL 4039 Detection disable fault level output when a detection disable category fault occur, value should be between 1.0mA to 3.6mA R/W Float 8
eLOOP_CURRENT_CONFIG_LEVEL 403A Configuration fault level output when a configuration category fault occur, value should be between 1.0mA to 3.6mA R/W Float 8
eLOOP_CURRENT_ADVISORY_LEVEL 403B Advisory fault level output when a advisory category fault occur, value should be between 1.0mA to 3.6mA R/W Float 8
Name ID Label Description Type Access Class