Name ID Label Description Type Access Class
dec_analog_value 4000 Loop current Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
dec_analog_alarm_code 4001 Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
dec_input_percent_range 4002 PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
dec_input_transfer_function 4003 Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
dec_input_upper_value 4004 PV URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R Float 32
dec_input_lower_value 4005 PV LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R Float 32
dec_range_units 4006 PV rnge unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
dec_sensor_value 4009 PV Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 10
dec_sensor_units 4007 PV Snsr unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 10
dec_sensor_upper_limit 400A PV USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 10
Name ID Label Description Type Access Class