Name ID Label Description Type Access Class
ZeroFlowCalReqControl 401F ZeroFlowCalReqControl Specifies the desired zero-flow calibration action. A zero-flow calibration process must be inactive in order to be started. The "Accept Result and Exit" selection is only valid when the status indicates "Completed Successfully." R/W Enum 8
ZeroFlowCalStatus 401C Zero calib status Current zero-flow calibration status indicator. R Enum 2
ZeroFlowCalReqDuration 401E Zero calib duration Specifies the zero-flow calibration duration. R/W Unsigned 0
DryCalVel 404D Zero calib velocity Factory-calibrated flow velocity (customer calibration not applied). This is the result of applying the factory calibration coefficients to the average weighted flow velocity (AvgWtdFlowVel). R Float 2
ZeroFlowCalResult 4021 Proposed offset Zero-flow calibration result. This value is only valid and can only be accepted when the ZeroFlowCalStatus is "Completed Successfully." When accepted, this value is used to update the FwdA0 and RevA0 data points. This value is not retained through a power cycle. R Float 2
ZeroFlowCalProgress 404E Zero calib progress Zero-flow calibration progress (percent complete). R Unsigned 2
HARTDevVar0Value 404F Uncorr volume flow rate HART Device Variable 0 (uncorrected volumetric flow rate) value. The units are specified by the 'HARTAO2VolFlowRateUnit' data point. R Float 2
HARTDevVar0XdcrLmtUpper 4050 HARTDevVar0XdcrLmtUpper Specifies the HART Device Variable 0 (uncorrected volumetric flow rate) upper transducer limit. The units are specified by the 'HARTDevVar0Units' data point. R Float 8
HARTDevVar0XdcrLmtLower 4051 HARTDevVar0XdcrLmtLower Specifies the HART Device Variable 0 (uncorrected volumetric flow rate) lower transducer limit . The units are specified by the 'HARTDevVar0Units' data point. R Float 8
HARTDevVar0MinimumSpan 4052 Device variable 0 minimum span R Float 0
Name ID Label Description Type Access Class