Loading…
Name ID Label Description Type Access Class
flowRateValue 4001 VF Volumetric Flow Rate R Float 10
flowRateUnits 4002 VF Sensor Units Volumetric Flow Rate Units R/W Enum 10
flowRateUSL 4003 VF Highcut Volumetric Flow Rate Upper Limit Maximum rate at which the meter will display and totalize. R/W Float 8
flowRateLSL 4004 VF Lowcut Volumetric Flow Rate Lower Limit Manimum rate at which the meter will display and totalize. R/W Float 8
flowRateMinimumSpan 4005 PV Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
flowRateDampingValue 4007 PV Damp Damp R/W Float 8
flowRatePDQ 4008 flowRate PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
flowRateClassification 4009 Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
flowRateStatus 400A flowRate Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
flowRateLS 400B flowRate LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
totalizerValue 4015 Total Total Volumetric Flow R Float 10
totalizerUnits 4016 TOT Sensor Units Volumetric Flow Total Units R/W Enum 10
totalizerPDQ 4019 totalizer PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
totalizerLS 401A totalizer LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
totalizerClassification 401B Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
totalizerStatus 401C Totalizer Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
tlfValue 401E TLF True Liquid Flow R Float 10
tlfUnits 401F TLF Units True Liquid Flow Units R Enum 10
tlfClassification 4022 Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
tlfPDQ 4023 TLF PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
tlfLS 4024 TLF LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
tlfStatus 4025 TLF Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
gvfValue 4027 GVF Gas Volume Fraction R Float 10
gvfUnits 4028 GVF Units Gas Volume Fraction Units R Enum 10
gvfClassification 402A Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
Name ID Label Description Type Access Class