Name ID Label Description Type Access Class
flow_value 1F7C Flo Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 10
flow_units 1F7B Flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 8
sensor_upper_limit 404E USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
sensor_lower_limit 404F LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
sensor_minimum_span 4050 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
sensor_damping_value 4051 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 8
analog_value 4007 AO1 Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
analog_alarm_code 4008 AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R/W Enum 64
input_percent_range 4009 Flo % Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
input_transfer_function 400A Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
input_units 400B Rnge unit Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value R Enum 4096
input_upper_value 400C URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
input_lower_value 400D LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
sensor_serial_number 400E Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 2048
total_totalizer 4012 Total totalizer Totalizer is not resetable directly. It can be forced while changing the unit R PackedAscii 18
daily_totalizer 4040 Daily totalizer Daily totalizer is resetable. Total totalizer will be unchanged at reset. R PackedAscii 18
totalizer_units 4010 Totalizer unit Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value R/W Enum 32
totalizer_para 4056 Para totalzer R/W Unsigned 4096
k_ref_value 404A k-factor ref R Float 2048
k_ref_unit 4057 Unit R/W Enum 8
local_display 4055 Local Display Here you can choose the local display. R/W Enum 32
decimals_format 404C Decimals R/W Enum 32
pulse_output_mode 4058 Pulse Output Mode Pulse Output Mode R/W Enum 32
sensor_type 4023 Snsr model Snsr model R Enum 2048
running_qm 4025 Total volume R Float 8
Name ID Label Description Type Access Class