Name ID Label Description Type Access Class
flow_value 1F7C Flo Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 10
flow_units 1F7B Flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 8
sensor_upper_limit 404E USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
sensor_lower_limit 404F LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
sensor_minimum_span 4050 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
sensor_damping_value 4051 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 8
analog_value 4007 AO1 Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
analog_alarm_code 4008 AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R/W Enum 64
input_percent_range 4009 Flo % Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
input_transfer_function 400A Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
input_units 400B Rnge unit Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value R Enum 4096
input_upper_value 400C URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
input_lower_value 400D LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
sensor_serial_number 400E Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 2048
total_totalizer 4012 Total totalizer Totalizer is not resetable directly. It can be forced while changing the unit R PackedAscii 18
daily_totalizer 4040 Daily totalizer Daily totalizer is resetable. Total totalizer will be unchanged at reset. R PackedAscii 18
totalizer_units 4010 Totalizer unit Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value R/W Enum 32
totalizer_para 4056 Para totalzer R/W Unsigned 4096
k_ref_value 404A k-factor ref R Float 2048
k_ref_unit 4057 Unit R/W Enum 8
local_display 4055 Local Display Here you can choose the local display. R/W Enum 32
decimals_format 404C Decimals R/W Enum 32
pulse_output_mode 4058 Pulse Output Mode Pulse Output Mode R/W Enum 32
sensor_type 4023 Snsr model Snsr model R Enum 2048
running_qm 4025 Total volume R Float 8
Q_max_value 4026 Freq max R Float 8
counterpara_change 4059 Para change R Unsigned 4096
T_min_value 4028 T-min R Float 8
T_max_value 4029 T-max R Float 8
model_code 402C Modelcode R PackedAscii 8
k_corr_value 404B k-factor corr R/W Float 2048
pulse_halfturn 404D Puls / 1/2Rotation R Unsigned 8
unique_device_type_code 07ED R/W Enum 4096
rosemount_model_code 07F5 R/W Enum 4096
rosemount_analytical_model_code 07F6 R/W Enum 4096
kayray_model_code 07F7 R/W Enum 4096
micro_motion_model_code 07F8 R/W Enum 4096
units_code 07E9 R/W Enum 4096
transfer_function_code 07EA R/W Enum 4096
material_code 07EC R/W Enum 4096
alarm_selection_code 07EB R/W Enum 4096
write_protect_code 07EE R/W Enum 4096
company_identification_code 07EF R/W Enum 4096
burst_mode_control_code 07F0 R/W Enum 4096
physical_signaling_codes 07F1 R/W Enum 4096
flag_assignment 07F2 R/W Enum 4096
operating_mode_code 07F3 R/W Enum 4096
analog_output_numbers_code 07F4 R/W Enum 4096
response_code 0096 Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. R/W Enum 129
comm_status 0098 Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. R/W BitEnum 131