Loading…
Name ID Label Description Type Access Class
sensor_serial_number 400C Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 2048
analog_alarm_code 4035 AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R/W Enum 64
transfer_function 1F84 Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 64
material_name 407D Medium R/W PackedAscii 8
xtrm_0_upper_sensor_limit 4032 USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
xtrm_0_lower_sensor_limit 4033 LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
xtrm_0_minimum_span 4034 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
xtrm_0_damping_value 4038 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 8
xtrm_0_analog_value 402F AO1 Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
xtrm_0_percent_range 4030 % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
Name ID Label Description Type Access Class