Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pressureMinimumSpan | 4012 | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pressureDampingValue | 4013 | Pres damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pressureUpdatePeriod | 4014 | Pressure Update Period | R | Time | 0 | |
pressureSerialNumber | 4015 | Pres snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 0 |
pressureLowerTrimPoint | 4016 | Pres Lower trim | Lower Trim Point- Applied process input at which the last lower trim of the device variable was performed. | R | Float | 0 |
pressureUpperTrimPoint | 4017 | Pres Upper trim | Upper Trim Point- Applied process input at which the last upper trim of the device variable was performed. | R | Float | 0 |
pressureTrimSupport | 4018 | Pres Trim support | Trim Points Supported- Indicates the trim points that are supported by the device variable during a trim procedure. | R | Enum | 0 |
pressureMinimumLTP | 4019 | Pres Min lower trim | Minimum Lower Trim Point- The lowest applied process value that can be used duirng a low trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 0 |
pressureMaximumLTP | 401A | Pres Max lower trim | Maximum Lower Trim Point- The highest applied process value that can be used duirng a low trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 0 |
pressureMinimumUTP | 401B | Pres Min upper trim | Minimum Upper Trim Point- The lowest applied process value that can be used duirng a high trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 0 |