Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
presetrestart_preset_func | 4059 | Restart Preset | Resetting of the preset meter | W | Unsigned | 2048 |
pipe_diameterUnit | 403F | Pipediameter Unit | Size in mm | R/W | Enum | 2048 |
pipe_diameterValue | 4004 | Pipediameter Value | Size of the detector | R/W | Enum | 2048 |
write_totalizer_TotPlusReset | 405A | Tot+ reset | Resetting the totaliser in main flow direction | W | Float | 2048 |
write_totalizer_TotMinusReset | 405B | Tot- reset | Resetting the totaliser reverse the main flow direction | W | Float | 2048 |
write_totalizer_TotDayReset | 405C | Tot Day reset | Resetting the totaliser in main flow direction (daily counter) | W | Float | 2048 |
write_totalizer_TotAllReset | 405D | Tot All reset | Resetting the totaliser in main flow direction (total counter) | W | Float | 2048 |
totalizer_TotPlus | 400E | Tot+ | Totaliser in main flow direction (total counter) | R | Float | 2050 |
totalizer_TotMinus | 400F | Tot- | Totaliser reverse the main flow direction | R | Float | 2050 |
totalizer_TotDay | 4010 | Tot Day | Totaliser in main flow direction (daily counter) | R | Float | 2050 |
analog_calibration_offset | 4032 | Analog Out. Offset | Calibration of the analog output (already done at the factory). Adjusting the offset at 4 mA. | R/W | Unsigned | 2048 |
analog_calibration_gain | 4033 | Analog Out. Gain | Calibration of the analog output (already done at the factory). Adjusting the range at 20 mA. | R/W | Unsigned | 2048 |
empty_pipe_calibration_value | 4028 | Empty-Pipe-Value | Measuring signal at fulfilled pipe. | R | Unsigned | 2048 |
empty_pipe_calibration_hysteresisUnit | 4085 | Empty-Pipe-H. Unit | Measuring signal unit in mV | R/W | Enum | 2048 |
empty_pipe_calibration_hysteresis | 4029 | Empty-Pipe-Hyst. | Adjusting the hysteresis value (recommended appr. 1000 mV) | R/W | Unsigned | 2048 |
volume_unit | 4006 | Volume Unit | Adjusting the volume unit for totalisation and preset | R/W | Enum | 2048 |
delete_error_list | 405E | delete | Resetting of error list | W | Unsigned | 2048 |
power_on_counter | 4014 | Power on counter | This value indicates the total switching ons of the meter | R | Unsigned | 2048 |
pulse_type | 400C | Pulse Type | Adjusting the pulse type. Closed (no pulse = low / pulse = high) as well as open (no pulse = high / pulse = low) | R/W | Enum | 2048 |
end_flow_simultion | 4058 | End Flow Simulation | Flow simulation of all outputs with the adjusted parameters | W | Unsigned | 2048 |
start_flow_simultion | 4052 | Start Flow Simulation | Start flow simulation | W | Unsigned | 2048 |
simulate_flow_plus100_percent | 4053 | Simulate Flow +100% | 100% of the full scale in main flow direction as well as relay 1 (forward) | W | Unsigned | 2048 |
simulate_flow_plus50_percent | 4054 | Simulate Flow +50% | 50% of full scale in main flow direction as well as relay 1 (forward) + relay 2 | W | Unsigned | 2048 |
simulate_flow_plus0_percent | 4055 | Simulate Flow 0% | 0% of full scale in main flow direction as well as relay 1 (forward) + relay 3 | W | Unsigned | 2048 |
simulate_flow_minus50_percent | 4056 | Simulate Flow -50% | 50% of the full scale reverse the main flow direction as well as relay 1 (backward) + relay 2 | W | Unsigned | 2048 |
Name | ID | Label | Description | Type | Access | Class |