Name ID Label Description Type Access Class
NumAnaIn 401C NumOAI Number of Analog Inputs supported by the instrument R Integer 2048
NumDigIn 401D NumODI Number of Digital Inputs supported by the instrument R Integer 2048
NumDigOut 401E NumODO Number of Digital Outputs supported by the instrument R Integer 2048
NumSamples 401F NumOSamples Number of Samples supported by the instrument R Integer 2048
ucNumDeviceStatus 4020 NumOStatus Number of Status texts supported by the instrument R Integer 2048
ucNumDecimals 4021 NumODec Number of Decimals in the Constant R ASCII 2048
channel 4022 Channel Selected channel, for which all displayed results and configuration changes are valid R/W Integer 2048
calib_set 4024 Calibration Set The selected Calibration Set, for which all configuration changes will apply to (not the same as the active Calibration Set) R/W Integer 2048
damping 4025 Damping Damping time, a time constant that can be set to stabilize the signal R/W Float 2048
offset 4026 Offset Offset adjustment of known error in the calibration R/W Float 2048
var_upr 4027 URV Upper measuring range value, represented by an output signal of 20 mA. R/W Float 2048
var_lwr 4028 LRV Lower measuring range value, represented by an output signal of 4 mA. R/W Float 2048
var_unit_code 4029 Unit Unit of variable R/W Enum 2048
var_alarm_selection 402A HART Alarm mode Defines the behaviour of the analog output when the transmitter has entered an unrecoverable error state. The following alarm modes are available: Hi: Sets and locks the analog output signal to approximately 22.5 mA, Lo: Sets and locks the analog output signal to approximately 3.3 mA, Hold last out valu: Locks the analog output signal to its present level, None: No action R/W Enum 2048
active_calib_set 4034 Active CalibSet Active Calibration Set R Integer 2050
dynamic_var_val 4033 Value The dynamic measuring value for the selected channel R Float 34
damping_value_factor 400F Damping value Value of the damping value R Float 34
percentofrange 4035 % of range The dynamic measuring value in relation to the Upper Measuring Range (URV) value R Float 34
var_current 4036 Analog out The dynamic analog output value from the transmitter for the selected channel R Float 34
rt_date 4037 RT date Transmitter system date in the format MM/DD/YYYY R/W HartDate 2048
rt_hour 4038 RT Hour Hour setting of the transmitter system clock R/W Integer 2048
rt_minute 4039 RT Minute Minute setting of the transmitter system clock R/W Integer 2048
rt_second 403A RT Sec Second setting of the transmitter system clock R/W Integer 2048
parameterindex 403B ParamIndex The index number of the selected parameter R/W Integer 2048
parameter_help_row 403F Param Help row The index to the parameter R/W Integer 2048
Name ID Label Description Type Access Class