Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
Actual_Position_Value | 4000 | Position | Instrument Primary Variable expressed in Engineering Units. | R | Float | 10 |
Actual_Position_Units | 4001 | Position Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
Actual_Position_Family | 4002 | Device family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 |
Actual_Position_Classification | 4003 | Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R/W | Enum | 0 |
Actual_Position_PDQ | 4004 | PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
Actual_Position_LS | 4005 | LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Actual_Position_Status | 4006 | Family status | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
Actual_Position_USL | 4007 | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R/W | Float | 0 |
Actual_Position_LSL | 4008 | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R/W | Float | 0 |
Actual_Position_MinimumSpan | 4009 | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R/W | Float | 0 |
Actual_Position_DampingValue | 400A | Temp damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
Actual_Position_SerialNumber | 400B | Sensor s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
Actual_Position_Simulated | 400C | Simulate | W | Enum | 2052 | |
Actual_Position_UpdatePeriod | 400D | Temp Update Period | R | Time | 0 | |
Desired_Position_Value | 400F | Setpoint | Instrument Primary Variable expressed in Engineering Units. Valid only if sensor. Calibration has been completed and accurate displacer and process fluid data have been entered in instrument memory | R | Float | 10 |
Desired_Position_Units | 4010 | Setpoint Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
Desired_Position_Family | 4011 | Device family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 |
Desired_Position_Classification | 4012 | Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R/W | Enum | 0 |
Desired_Position_PDQ | 4013 | PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
Desired_Position_LS | 4014 | LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Desired_Position_Status | 4015 | Family status | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
Desired_Position_USL | 4016 | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R/W | Float | 0 |
Desired_Position_LSL | 4017 | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R/W | Float | 0 |
Desired_Position_MinimumSpan | 4018 | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R/W | Float | 0 |
Desired_Position_DampingValue | 4019 | Temp damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
Desired_Position_SerialNumber | 401A | Sensor s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
Desired_Position_Simulated | 401B | Simulate | W | Enum | 2052 | |
Desired_Position_UpdatePeriod | 401C | Temp Update Period | R | Time | 0 | |
Torque_Value | 401E | Torque | Instrument Primary Variable expressed in Engineering Units. | R | Float | 10 |
Torque_Units | 401F | Torque Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
Torque_Family | 4020 | Device family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 |
Torque_Classification | 4021 | Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R/W | Enum | 0 |
Torque_PDQ | 4022 | PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
Torque_LS | 4023 | LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Torque_Status | 4024 | Family status | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
Torque_USL | 4025 | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R/W | Float | 0 |
Torque_LSL | 4026 | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R/W | Float | 0 |
Torque_MinimumSpan | 4027 | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R/W | Float | 0 |
Torque_DampingValue | 4028 | Temp damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
Torque_SerialNumber | 4029 | Sensor s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
Torque_Simulated | 402A | Simulate | W | Enum | 2052 | |
Torque_UpdatePeriod | 402B | Temp Update Period | R | Time | 0 | |
Raw_Position_Value | 402D | Raw Position | Instrument Primary Variable expressed in Engineering Units. | R | Float | 10 |
Raw_Position_Units | 402E | Raw Position Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
Raw_Position_Family | 402F | Device family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 |
Raw_Position_Classification | 4030 | Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R/W | Enum | 0 |
Raw_Position_PDQ | 4031 | PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
Raw_Position_LS | 4032 | LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Raw_Position_Status | 4033 | Family status | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
Raw_Position_USL | 4034 | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R/W | Float | 0 |
Name | ID | Label | Description | Type | Access | Class |