Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
Pst_Success | 4022 | PST Finish | PST finish without error | R/W | Enum | 1025 |
reserved_1 | 4023 | R/W | Integer | 1026 | ||
control_mode | 2772 | Control Mode | Control the valve in either Discrete or Modulated mode. | R/W | Enum | 1026 |
flop_mode | 4024 | DisplayMode | Show %closed or %open on IMVS display. | R/W | Enum | 1026 |
valve_type | 4025 | Valve Type | IMVS can work with linear and rotary valves. | R/W | Enum | 1026 |
actuator_type | 4026 | Actuator | IMVS can work with single and double acting actuators. | R/W | Enum | 1026 |
solenoid1_inv | 4027 | Solenoid1 | IMVS can invert solenoid 1 input. | R/W | Enum | 1026 |
solenoid2_inv | 4028 | Solenoid2 | IMVS can invert solenoid 2 input. | R/W | Enum | 1026 |
open_rotation | 4029 | Rotation | IMVS can operate valve that rotates CW or CCW to open. | R/W | Enum | 1026 |
cal_status | 402A | Position Calibration Status | Denotes the status of position calibration once completed. | R/W | Unsigned | 10 |
Name | ID | Label | Description | Type | Access | Class |