Loading…
Name ID Label Description Type Access Class
var_upper_range_value 400A Up.Range Upper Range Limit R/W Float 32
var_lower_range_value 400B Lo.Range Lower Range Limit R/W Float 32
var_sensor_serial_number 400C Sensor Serial No Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 2048
var_distance_units 400D m act. distance unit R Enum 8
var_distance_value 400E Dist act. distance R Float 10
var_frequency_unit 400F Hz unit of frequency raw value R Enum 8
var_frequency_value 4010 Freq act. frequency raw value R Float 10
var_intensity_unit 4011 unit of signal intensity R Enum 8
var_intensity_value 4012 Intensity act. intensity of measure signal R Float 10
var_current_upper_trim 4013 Up.Trim current output upper trim R/W Float 64
Name ID Label Description Type Access Class