Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
var_dd_fSensorValue | 4000 | Live Rate | Display of Active unaveraged ReadIn rate.(Cps live) | R | Float | 2050 |
var_dd_fPV1 | 4003 | PV | Digital representation of measured process value(PV->Primary Variable). | R/W | Float | 10 |
var_dd_eDeviceStatus | 4007 | Device Status | Represents the Status of the Field Device in accordance to NE107 Normal Valid output signal. Maintenance required(M) Still valid output signal. Out of specification(S) Signal out of specified range. Function check(C) Temporary non-valid output signal. Failure(F) Non-valid output signal. | R | Enum | 10 |
var_dd_eCurrentLoopStatus | 4008 | Current AO Status | Actual Current Loop Status | R | Enum | 10 |
var_dd_eDataQuality | 400B | Data Quality | Qualità dati di processo - Indica la qualità complessiva dei dati di processo del valore della variabile dispositivo. | R | Enum | 10 |
var_dd_eLimitStatus | 400C | Limit Status | Stato limite - Indica se la variabile dispositivo è limitata (ovvero non risponde a un processo). | R | Enum | 10 |
var_dd_beDeviceFamilyStatus | 400D | Family Status | Stato famiglia dispositivo - Indica informazioni aggiuntive sullo stato su una variabile dispositivo per una famiglia del dispositivo specifica. | R | BitEnum | 10 |
var_dd_fDensitySuspension | 400E | Density Suspension | R | Float | 10 | |
var_dd_fCpsZero | 400F | Io Rate | R | Float | 10 | |
var_dd_eMeasurementStatus | 4010 | Measurement Status | Display of actual measurement status. | R | Enum | 10 |
var_dd_fMeasPointRate1 | 4011 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate2 | 4012 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate3 | 4013 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate4 | 4014 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate5 | 4015 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate6 | 4016 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate7 | 4017 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate8 | 4018 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate9 | 4019 | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate10 | 401A | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_dd_fMeasPointRate11 | 401B | Meas Rate | Rate for adjustment of meas point. | R | Float | 10 |
var_ds_uiOperatingHours | 401C | Operating Hours | Operating Hours- The counter value represents the accumulated release time of operation in hours | R/W | Unsigned | 34 |
var_dd_dtActiveDate | 401E | Date | Actual system date (mm/dd/yyyy). | R/W | HartDate | 10 |
var_dd_ascActiveTime | 401F | Time | Actual system time (hh:mm:ss). | R/W | ASCII | 10 |
var_dd_eOperatingMode | 4020 | Operating Mode | Displays actual System Operating Mode. | R | Enum | 2051 |