名称 ID 标签 描述 类型 访问 分类
PROPORTIONAL_GAIN 4060 Kp = PROPORTIONAL GAIN -The gain of the proportional contri- bution of the con- trol algorithm. 读/写 浮点 16
INTEGRAL_TIME 4061 Tr = INTEGRAL TIME -The gain of the integral contribution of the control algorithm. 读/写 浮点 16
DERIVATIVE_TIME 4062 Td = DERIVATIVE TIME -The gain of the deriva- tive contribution of the control algo- rithm. 读/写 浮点 16
MV_HIGH_LIMIT 405A High limit MV HIGH LIMIT -The maximum value to which MV should be allowed to go. This range is physically limited: 0% (4 mA) to 106.25% (21 mA) 读/写 浮点 16
MV_LOW_LIMIT 4059 Low limit MV LOW LIMIT -The minimum value to which MV should be allowed to go. This range is physically limited: -0.625% (3.9 mA) to 100.00% (20 mA) 读/写 浮点 16
MV_ROC_LIMIT 4065 Out Chg/s MV RATE-OF-CHANGE LIMIT -the maximum (absolute) rate of change of the MV 读/写 浮点 16
POWER_UP_SETPOINT_PERCENT_RANGE 4068 Power-up SP% POWER-UP SETPOINT -the value in per- cent which the set- point will assume when power once a- gain is applied af- ter a power inter- ruption 读/写 浮点 16
POWER_UP_OUTPUT 4069 Safety out POWER-UP MV -the value in percent which the manipu- lated variable will assume when a device failure is detected or when power once again is applied af- ter a power inter- ruption 读/写 浮点 16
cut_off 4006 Cutoff= Cutoff point -used in flow applications with square-root transfer function to disable the square root extraction for values below this low flow cutoff point 读/写 浮点 32
cut_off_mode 4007 Cutoff mode Cutoff mode -The mode by which the flow between 0% and the cutoff point is calculated: Hard -flow is 0%, Bumpless -flow is linearily inter- polated 读/写 枚举 32
indic_variable_first 4070 First Var.= First indication -the first of the two variables that are indicated in the local display. 读/写 枚举 256
indic_variable_second 4071 Second Var.= Second indication -the first of the two variables that are indicated in the local display. 读/写 枚举 256
chg_cnt_range 4074 LRV/URV Change counter range -counts the number of changes made to the range (Lower or upper value). 整型 2048
chg_cnt_function 4075 Function Change counter func- tion -counts the number of changes made to the transfer function. 整型 2048
chg_cnt_trim_4 4076 Trim 4mA Change counter, trim 4 mA -counts the number of trims made to the 4 mA point of the output current. 整型 2048
chg_cnt_trim_20 4077 Trim 20mA Change counter, trim 20 mA -counts the number of trims made to the 20 mA point of the output cur- rent. 整型 2048
chg_cnt_trim_lower 4078 Trim lower Change counter, trim lower -counts the number of trims made to the lower point of the pressure in- put (lower or zero trim). 整型 2048
chg_cnt_trim_upper 4079 Trim upper Change counter, trim upper -counts the number of trims made to the upper point of the pressure in- put. 整型 2048
chg_cnt_mode 407A XMTR/PID Change counter, mode -counts the number of changes made to the operation mode (transmitter / con- troller). 整型 2048
chg_cnt_characterization 407B Trim Char. Change counter, characterization -counts the number of trims made to the characterization of the pressure input. 整型 2048
chg_cnt_multidrop 407C Multidrop Change counter, multidrop -counts the number of changes made to the communication mode (multidrop / single unit). 整型 2048
chg_cnt_total 407D Totalization Change counter, to- tal -counts the num- ber of changes made to the totalizer configuration, or resets; manual or power-off. 整型 2048
bd_sensors_ordering_code 407F CODE# Ordering code -the ordering code of the device, should be maintained to match the current hardware configuration 读/写 ASCII 2048
user_unit_string 4082 User unit string Process variable unit -The engineer- ing unit associated with the controller process variable and setpoint 读/写 ASCII 34
user_units_code 4083 User unit 读/写 枚举 34
名称 ID 标签 描述 类型 访问 分类