Name ID Label Description Type Access Class
differenceFamily 4038 Temp Dev fmly Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
differenceClassification 4039 Temp Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
differencePDQ 403A Temp PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
differenceLS 403B Temp LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
differenceStatus 403C Temp Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2
differenceUSL 403D Temp USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
differenceLSL 403E Temp LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
differenceMinimumSpan 403F Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
differenceDampingValue 4040 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 0
differenceSerialNumber 4041 Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 0
RJ_value 4049 RJ value device temperature for temperature compensation. R Float 2050
RJ_preset_value_1 404B RJ preset value 1 Use this function to define the fixed preset value for temperature compensation.-50 to +87℃ R/W Float 2048
RJ_preset_value_2 404C RJ preset value 2 Use this function to define the fixed preset value for temperature compensation.-50 to +87℃ R/W Float 2048
Sensor_type_1 404E Sensor type 1 Settings for sensor input 1. R/W Enum 2050
Sensor_type_2 4043 Sensor type 2 Settings for sensor input 2. R/W Enum 2050
Connection_type_1 404F Connection type 1 Use this function to select the connection type for the sensor 1. R/W Enum 2050
Connection_type_2 4050 Connection type 2 Use this function to select the connection type for the sensor 2. R/W Enum 2050
Reference_junction_1 4051 Reference junction 1 Use this function to select reference juntion measurement for temperature compensation of thermocouples(TC). R/W Enum 2050
Reference_junction_2 4052 Reference junction 2 Use this function to select reference juntion measurement for temperature compensation of thermocouples(TC). R/W Enum 2050
Channel_diagnostics_1 4053 Channel diagnostics 1 Use this function to display the diagnostics messages of sensor channel. R Enum 2050
Channel_diagnostics_2 4054 Channel diagnostics 2 Use this function to display the diagnostics messages of sensor channel. R Enum 2050
R0_value_1 4055 R0 value 1 Use this function to set RTD to zero in the ice-water mixture.range 0.9~1.1 R/W Float 2048
R0_value_2 4056 R0 value 2 Use this function to set RTD to zero in the ice-water mixture.range 0.9~1.1 R/W Float 2048
Calibrate_two_wire_zero 405B Calibrate two wire zero R/W Unsigned 0
Calibrate_RTD_TC 405D Calibrate RTD/TC R/W Unsigned 0
Result_calibrate 405F Result calibrate R Unsigned 0
Processor_function_code 4061 Processor function code R/W Unsigned 4096
Alarm_direction 4063 Alarm Direction R/W Enum 2048
Low_alarm 4066 Low Alarm range 3.5~3.75 mA R/W Float 2048
High_alarm 4067 High Alarm range 21.75~23 mA R/W Float 2048
Calibrate_point_0_500R_1 406A Calibrate Point of 0_500R 1 Range 350.0 ~ 490.0 Preset Point of 0~500R R/W Float 2050
Calibrate_point_0_500R_2 406B Calibrate Point of 0_500R 2 Range 350.0 ~ 490.0 Preset Point of 0~500R R/W Float 2048
Calibrate_point_0_4000R_1 406C Calibrate Point of 0_4000R 1 Range 2500.0 ~ 3900.0 Preset Point of 0~4000R R/W Float 2048
Calibrate_point_0_4000R_2 406D Calibrate Point of 0_4000R 2 Range 2500.0 ~ 3900.0 Preset Point of 0~4000R R/W Float 2048
Calibrate_point_100mV_1 406E Calibrate Point of 100mV 1 Range 10.0 ~ 19.0 Preset Point of -100~+100mV R/W Float 2048
Calibrate_point_100mV_2 406F Calibrate Point of 100mV 2 Range 10.0 ~ 19.0 Preset Point of -100~+100mV R/W Float 2048
device_status 0097 Device status Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process R BitEnum 131
units_code 07E9 R/W Enum 4096
transfer_function_code 07EA R/W Enum 4096
material_code 07EC R/W Enum 4096
alarm_selection_code 07EB R/W Enum 4096
write_protect_code 07EE R/W Enum 4096
company_identification_code 07EF R/W Enum 4096
physical_signaling_codes 07F1 R/W Enum 4096
flag_assignment 07F2 R/W Enum 4096
operating_mode_code 07F3 R/W Enum 4096
analog_output_numbers_code 07F4 R/W Enum 4096
loop_current_mode_codes 07F9 R/W Enum 4096
extended_device_status_codes 07FA R/W Enum 4096
lock_device_codes 07FC R/W Enum 4096
Name ID Label Description Type Access Class