Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
sensor1Value | 4002 | Sensor1 Value | R | Float | 2 | |
sensor1Units | 4003 | Sensor1 Unit | R/W | Enum | 0 | |
sensor1Family | 4004 | Temp Dev fmly | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 0 |
sensor1Classification | 4005 | Temp Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
sensor1PDQ | 4006 | Temp PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
sensor1LS | 4007 | Temp LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 2 |
sensor1Status | 4008 | Temp Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 2 |
sensor1USL | 4009 | Temp USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor1LSL | 400A | Temp LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor1MinimumSpan | 400B | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor1DampingValue | 400C | Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
sensor1SerialNumber | 400D | Sensor1 snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 0 |
sensor2Value | 400F | Sensor2 Value | R | Float | 2 | |
sensor2Units | 4010 | Sensor2 Unit | R/W | Enum | 0 | |
sensor2Family | 4011 | Temp Dev fmly | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 0 |
sensor2Classification | 4012 | Temp Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
sensor2PDQ | 4013 | Temp PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
sensor2LS | 4014 | Temp LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 2 |
sensor2Status | 4015 | Temp Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 2 |
sensor2USL | 4016 | Temp USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor2LSL | 4017 | Temp LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor2MinimumSpan | 4018 | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor2DampingValue | 4019 | Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
sensor2SerialNumber | 401A | Sensor2 snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 0 |
temperatureValue | 401C | Dev Temp Value | R | Float | 2 | |
temperatureUnits | 401D | Snsr temp unit | Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. | R/W | Enum | 0 |
temperatureFamily | 401E | Device family | R | Enum | 0 | |
temperatureClassification | 401F | Temp Class | R | Enum | 0 | |
temperaturePDQ | 4020 | Temp PDQ | R | Enum | 2 | |
temperatureLS | 4021 | Temp LS | R | Enum | 2 | |
temperatureStatus | 4022 | Temp Dev Stat | R | BitEnum | 2 | |
temperatureUSL | 4023 | Temp USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
temperatureLSL | 4024 | Temp LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
temperatureMinimumSpan | 4025 | Temp min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
temperatureDampingValue | 4026 | Temp damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
temperatureSerialNumber | 4027 | Temp snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 0 |
averageValue | 4029 | Average Value | R | Float | 2 | |
averageUnits | 402A | Average Unit | R/W | Enum | 0 | |
averageFamily | 402B | Temp Dev fmly | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 0 |
averageClassification | 402C | Temp Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
averagePDQ | 402D | Temp PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
averageLS | 402E | Temp LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 2 |
averageStatus | 402F | Temp Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 2 |
averageUSL | 4030 | Temp USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
averageLSL | 4031 | Temp LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
averageMinimumSpan | 4032 | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
averageDampingValue | 4033 | Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
averageSerialNumber | 4034 | Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 0 |
differenceValue | 4036 | Difference Value | R | Float | 2 | |
differenceUnits | 4037 | Difference Unit | R/W | Enum | 0 | |
Name | ID | Label | Description | Type | Access | Class |