Name ID Label Description Type Access Class
sensor1Value 4002 Sensor1 Value R Float 2
sensor1Units 4003 Sensor1 Unit R/W Enum 0
sensor1Family 4004 Temp Dev fmly Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
sensor1Classification 4005 Temp Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
sensor1PDQ 4006 Temp PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
sensor1LS 4007 Temp LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
sensor1Status 4008 Temp Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2
sensor1USL 4009 Temp USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
sensor1LSL 400A Temp LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
sensor1MinimumSpan 400B Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
sensor1DampingValue 400C Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 0
sensor1SerialNumber 400D Sensor1 snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 0
sensor2Value 400F Sensor2 Value R Float 2
sensor2Units 4010 Sensor2 Unit R/W Enum 0
sensor2Family 4011 Temp Dev fmly Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
sensor2Classification 4012 Temp Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
sensor2PDQ 4013 Temp PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
sensor2LS 4014 Temp LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
sensor2Status 4015 Temp Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2
sensor2USL 4016 Temp USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
sensor2LSL 4017 Temp LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
sensor2MinimumSpan 4018 Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
sensor2DampingValue 4019 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 0
sensor2SerialNumber 401A Sensor2 snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 0
temperatureValue 401C Dev Temp Value R Float 2
temperatureUnits 401D Snsr temp unit Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. R/W Enum 0
temperatureFamily 401E Device family R Enum 0
temperatureClassification 401F Temp Class R Enum 0
temperaturePDQ 4020 Temp PDQ R Enum 2
temperatureLS 4021 Temp LS R Enum 2
temperatureStatus 4022 Temp Dev Stat R BitEnum 2
temperatureUSL 4023 Temp USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
temperatureLSL 4024 Temp LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
temperatureMinimumSpan 4025 Temp min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
temperatureDampingValue 4026 Temp damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 0
temperatureSerialNumber 4027 Temp snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 0
averageValue 4029 Average Value R Float 2
averageUnits 402A Average Unit R/W Enum 0
averageFamily 402B Temp Dev fmly Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
averageClassification 402C Temp Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
averagePDQ 402D Temp PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
averageLS 402E Temp LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
averageStatus 402F Temp Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2
averageUSL 4030 Temp USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
averageLSL 4031 Temp LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
averageMinimumSpan 4032 Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
averageDampingValue 4033 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 0
averageSerialNumber 4034 Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 0
differenceValue 4036 Difference Value R Float 2
differenceUnits 4037 Difference Unit R/W Enum 0
Name ID Label Description Type Access Class