Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
sensor1Value | 4002 | Sensor1 Value | R | Float | 2 | |
sensor1Units | 4003 | Sensor1 Unit | R/W | Enum | 0 | |
sensor1Family | 4004 | Temp Dev fmly | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 0 |
sensor1Classification | 4005 | Temp Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
sensor1PDQ | 4006 | Temp PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
sensor1LS | 4007 | Temp LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 2 |
sensor1Status | 4008 | Temp Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 2 |
sensor1USL | 4009 | Temp USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor1LSL | 400A | Temp LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
sensor1MinimumSpan | 400B | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
Name | ID | Label | Description | Type | Access | Class |