Name ID Label Description Type Access Class
extsw 400B ExtSw mode R/W Enum 2048
si_unit 400C SI Unit R/W Enum 2048
alarm_state 400D Alarm Status Alarm Status- Displays the current alarm output status. R BitEnum 35
co_state 400E Contact Output Status Contact Output Status- Displays the status of the contact output. --Open: The contact output circuit is open. --Closed: The contact output circuit is closed. --Sim Open: The contact output circuit is open in simulation mode. --Sim Closed: The contact output circuit is closed in simulation mode. R/W Enum 34
alarm_pv_conf 4010 Output Alarm Output Alarm- Configures the output alarm. --No Alarm: Output alarm is not used. --Low Limit: If the output is below the low limit for the output alarm, the alarm is activated. --High Limit: If the output is above the high limit for the output alarm, the alarm is activated. --Low/High Limit: If the output is either below the low limit or above the high limit for the output alarm, the alarm is activated. R/W Enum 2048
alarm_pv_low 4011 Output Alarm Low Limit Output Alarm Low Limit- Sets the low limit for the Output Alarm. R/W Float 2048
alarm_pv_high 4012 Output Alarm High Limit Output Alarm High Limit- Sets the high limit for the Output Alarm. R/W Float 2048
alarm_temp_conf 4013 Sensor Temp. Alarm Sensor Temp. Alarm- Configures the temperature alarm. --No Alarm: Sensor temperature alarm is not used. --Low Limit: If the sensor temperature is below the low limit for the sensor temperature alarm, the alarm is activated. --High Limit: If the sensor temperature is above the high limit for the sensor temperature alarm, the alarm is activated. --Low/High Limit: If the sensor temperature is either below the low limit or above the high limit for the sensor temperature alarm, the alarm is activated. R/W Enum 2048
alarm_temp_low 4014 Sensor Temp. Alarm Low Limit Sensor Temp. Alarm Low Limit- Sets the low limit for the Sensor Temp. Alarm. R/W Float 2048
alarm_temp_high 4015 Sensor Temp. Alarm High Limit Sensor Temp. Alarm High Limit- Sets the high limit for the Sensor Temp. Alarm. R/W Float 2048
co_type 4016 Contact Output Mode Contact Output Mode- Sets the contact output mode to either Normally Open or Normally Closed. --Normally Open: Contacts are normally open, but close when an alarm is detected. --Normally Closed: Contacts are normally closed, but open when an alarm is detected. R/W Enum 2048
alarm_select 4017 Contact Output ON/OFF Contact Output ON/OFF- Selects the alarms to reflect the contact output. R/W BitEnum 2048
alarm_select_output_low 40DD Output Low Output Low- This parameter determines whether or not detection of the output low-limit alarm is connected to the contact output circuit. R/W Enum 2048
alarm_select_output_high 40DE Output High Output High- This parameter determines whether or not detection of the output high-limit alarm is connected to the contact output circuit. R/W Enum 2048
alarm_select_temp_low 40DF Sensor Temp. Low Sensor Temp. Low- This parameter determines whether or not detection of the sensor's low-limit temperature alarm is connected to the contact output circuit. R/W Enum 2048
alarm_select_temp_high 40E0 Sensor Temp. High Sensor Temp. High- This parameter determines whether or not detection of the sensor's high-limit temperature alarm is connected to the contact output circuit. R/W Enum 2048
alarm_select_dummy 40E1 alarm_select_dummy R Unsigned 4096
disp_mode 4018 Display Mode Display Mode- Sets the device indicator's method of display. --%: Displays the currently measured pressure as a percentage of the preset measurement range. --Pressure: Displays the currently measured pressure in the selected pressure unit. --Scale: Displays the measured value (flow rate, level etc.) in user-selected or user-defined units. R/W Enum 256
disp_sqrt 4019 Display Function Display Function- Sets the type of analog output from the device. --Linear: Displays PV by linear scale. --Square root: Displays flow by square root extraction. R/W Enum 256
disp_unit 401A Disp. Unit Disp. Unit- Selects the engineering unit displayed on the indicator of the device. Valid when Scale is selected for Display Mode. R/W Enum 256
disp_exponent 401B Exponent Exponent- Selects the exponent (X10, X100, etc.) displayed on the indicator of the device. Valid when Scale is selected for Display Mode. R/W Enum 256
cutoff_mode 401C Cutoff Mode Cutoff Mode- Displays one of the following Cutoff Mode status indications. --Def (7.1%Lin): The default Cutoff Mode is in effect. (Flow mode is the default value, dropout is linear, and cutoff point is 7.1%) --Zero Flow & Dflt: Dropout is zero and flow mode is the default value. --Lin. Flow & Dflt: Dropout is linear and flow mode is the default value --Zero Flow & Bi-dir: Dropout is zero and flow mode is bi-directional. --Lin. Flow & Bi-dir: Dropout is linear and flow mode is bi-directional. --Dropout: Determines behavior below the cutoff value (either zero or linear). --Flow mode: Determines the method of calculating the flow output, either default (square root of positive output) or bi-directional (square root of both positive and negative outputs). R Enum 64
dropout_point 401D Cutoff Point Cutoff Point- Displays the cutoff point (%) that is valid when Square Root is selected as the Xfer fnctn. R/W Float 64
eu_lower_value 401E EULO (0%) EULO (0%)- The value displayed on the indicator of the device when the output from the device is 0%. Valid when Scale is selected for Display Mode. R/W Float 256
eu_upper_value 401F EUHI (100%) EUHI (100%)- The value displayed on the indicator of the device when the output from the device is 100%. Valid when Scale is selected for Display Mode. R/W Float 256
out_lower_limit 4020 Output Low Limit Output Low Limit- Sets the low limit for the Loop current. R/W Float 64
out_upper_limit 4022 Output High Limit Output High Limit- Sets the high limit for the Loop current. R/W Float 64
type_code 4023 Measurement Type Measurement Type- Displays the device's sensor type. --DP: Differential pressure --GP: Gauge pressure --AP: Absolute pressure R/W Enum 2048
prom_id 4024 PROM No. PROM No.- Displays PROM No. used for the device. R ASCII 2048
conf_de_type 4025 SFN Communicator R/W Enum 2048
userunit 4026 User Unit User Unit- Sets the user-defined unit displayed on the indicator of the device. Valid when Scale is selected for Display Mode. R/W ASCII 256
status_record_0 4027 Status Record 0 R BitEnum 2049
status_record_1 4028 Status Record 1 R BitEnum 2049
status_record_2 4029 Status Record 2 R BitEnum 2049
status_record_3 402A Status Record 3 R BitEnum 2049
zero_correct1 402B 1 (Latest) 1 (Latest)- Displays the zero corrected value as a percentage of the Upper Range Limit. R Float 2048
zero_correct2 402C 2 2- Displays the zero corrected value as a percentage of the Upper Range Limit. R Float 2048
zero_correct3 402D 3 3- Displays the zero corrected value as a percentage of the Upper Range Limit. R Float 2048
zero_correct4 402E 4 4- Displays the zero corrected value as a percentage of the Upper Range Limit. R Float 2048
zero_correct5 402F 5 5- Displays the zero corrected value as a percentage of the Upper Range Limit. R Float 2048
zero_correct_current 4030 Zero Correct Current R Float 2048
zero_correct_count 4031 Count R Integer 2048
sw_write_protect 4032 Software Write Protect Software Write Protect- Displays the status of software write protection. R/W Enum 2048
hw_write_protect 4033 Hardware Write Protect Hardware Write Protect- Displays the status of hardware write protection. R Enum 2048
analog_output_conf 4021 Analog Output Configuration R Enum 2048
hardware_equipment 400F Hardware Equipment R/W BitEnum 2048
fw_sw_version 4034 Software Version R Unsigned 2048
height 40B4 Height Height- Compensates for the effects of temperature change on the fill fluid of the remote sealed transmitter. User must enter the distance between the flanges in order to use this compensation. R/W Float 32
set_output_value 4035 Set Output Value R/W Float 4096
set_burnout_sim 40B5 Burnout Simulation R/W Enum 4096