Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
disp_exponent | 401B | Exponent | Exponent- Selects the exponent (X10, X100, etc.) displayed on the indicator of the device. Valid when Scale is selected for Display Mode. | R/W | Enum | 256 |
cutoff_mode | 401C | Cutoff Mode | Cutoff Mode- Displays one of the following Cutoff Mode status indications. --Def (7.1%Lin): The default Cutoff Mode is in effect. (Flow mode is the default value, dropout is linear, and cutoff point is 7.1%) --Zero Flow & Dflt: Dropout is zero and flow mode is the default value. --Lin. Flow & Dflt: Dropout is linear and flow mode is the default value --Zero Flow & Bi-dir: Dropout is zero and flow mode is bi-directional. --Lin. Flow & Bi-dir: Dropout is linear and flow mode is bi-directional. --Dropout: Determines behavior below the cutoff value (either zero or linear). --Flow mode: Determines the method of calculating the flow output, either default (square root of positive output) or bi-directional (square root of both positive and negative outputs). | R | Enum | 64 |
dropout_point | 401D | Cutoff Point | Cutoff Point- Displays the cutoff point (%) that is valid when Square Root is selected as the Xfer fnctn. | R/W | Float | 64 |
eu_lower_value | 401E | EULO (0%) | EULO (0%)- The value displayed on the indicator of the device when the output from the device is 0%. Valid when Scale is selected for Display Mode. | R/W | Float | 256 |
eu_upper_value | 401F | EUHI (100%) | EUHI (100%)- The value displayed on the indicator of the device when the output from the device is 100%. Valid when Scale is selected for Display Mode. | R/W | Float | 256 |
out_lower_limit | 4020 | Output Low Limit | Output Low Limit- Sets the low limit for the Loop current. | R/W | Float | 64 |
out_upper_limit | 4022 | Output High Limit | Output High Limit- Sets the high limit for the Loop current. | R/W | Float | 64 |
type_code | 4023 | Measurement Type | Measurement Type- Displays the device's sensor type. --DP: Differential pressure --GP: Gauge pressure --AP: Absolute pressure | R/W | Enum | 2048 |
prom_id | 4024 | PROM No. | PROM No.- Displays PROM No. used for the device. | R | ASCII | 2048 |
conf_de_type | 4025 | SFN Communicator | R/W | Enum | 2048 | |
Name | ID | Label | Description | Type | Access | Class |