Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
lower_trim_value | 400C | LowTrim | This value is lower trim point of two point trim | R | Float | 2048 |
upper_trim_value | 400D | UpTrim | This value is upper trim point of two point trim | R | Float | 2048 |
point_position | 401F | Trim Mode | Select trim mode | R/W | Enum | 8 |
current_value | 4021 | Current trim value | Current PV value | R/W | Float | 2048 |
apply_value | 4022 | Apply trim value | Change current value to apply value for trim | R/W | Float | 2048 |
Dev_Xmtr_Var_Code | 4024 | Xmtr Variable | Device transmitter variable code | W | Enum | 8 |
apt_3100_Sen_Type_Code | 4025 | Selected Xmtr Sensor | Pressure Tranmitter Sensor Type Code | R | Enum | 8 |
lcd_display_mode | 4027 | LCD Display Mode | LCD mode | R/W | Enum | 8 |
eng_xfer_ftn | 401D | Engr. Xfer Fnctn | R/W | Enum | 8 | |
decimal_place | 402B | Decimal Place | R/W | Enum | 8 | |
eng_range_unit | 400E | Engr. Range Unit | R/W | Enum | 8 | |
eng_lower_range | 401B | Engr. LRV | R/W | Float | 2048 | |
eng_upper_range | 401C | Engr. URV | R/W | Float | 2048 | |
eng_user_defined_unit | 402E | User Defined unit | R/W | ASCII | 2048 | |
zero_adjust_value | 4031 | Adjust value | Change current PV to zero adjustmet value | R/W | Float | 2048 |
adjust_division | 4032 | Adjust Mode | Select Zero Adjust mode | R/W | Enum | 8 |
cut_off_value | 4037 | Cut-Off Value | R/W | Float | 2048 | |
cut_off_mode | 4038 | Cut-OFF Mode | R/W | Enum | 8 | |
temp_unit | 403C | Temp Unit | W | Enum | 8 | |
pressure_unit | 403D | Pressure Unit | W | Enum | 8 | |
vol_flow_unit | 403E | Volumetric flow Unit | W | Enum | 8 | |
velocity_unit | 403F | Velocity Unit | W | Enum | 8 | |
volume_unit | 4040 | Velocity Unit | W | Enum | 8 | |
length_unit | 4041 | Length Unit | W | Enum | 8 | |
time_unit | 4042 | Time Unit | W | Enum | 8 | |
mass_flow_unit | 4043 | Mass & Mass Flow | W | Enum | 8 | |
mass_vol_unit | 4044 | Mass per volume | W | Enum | 8 | |
eng_range_unit_write | 4045 | RngUnit | W | Enum | 8 | |
sensor_value | 400F | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 10 |
sensor_units | 4010 | PV Snsr unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 8 |
sensor_upper_limit | 4013 | PV USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
sensor_lower_limit | 4012 | PV LSL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
sensor_minimum_span | 4014 | PV Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
sensor_damping_value | 4047 | PV Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 8 |
sensor2_value | 4048 | SV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 10 |
sensor2_units | 4049 | PV Snsr unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 8 |
sensor3_value | 404A | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 10 |
sensor3_units | 404B | PV Snsr unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 8 |
sensor4_value | 404C | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 10 |
sensor4_units | 404D | PV Snsr unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 8 |
analog_value | 4018 | AO | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes | R/W | Float | 66 |
analog_alarm_code | 4019 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
analog_damping_value | 404E | AO1 Added damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 8 |
analog_units | 404F | Anlog unit | R | Enum | 64 | |
analog_upper_endpoint_value | 4050 | AO1 Hi end pt | R | Float | 8 | |
analog_lower_endpoint_value | 4051 | AO1 Lo end pt | R | Float | 8 | |
input_percent_range | 4052 | PV % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
input_transfer_function | 4053 | Xfer fnctn | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. | R/W | Enum | 32 |
input_units | 4054 | PV rnge unit | Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value | R | Enum | 32 |
input_upper_value | 4055 | PV URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
Name | ID | Label | Description | Type | Access | Class |