Loading…
Name ID Label Description Type Access Class
ScrData_DataQuality 4079 PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 0
ScrData_LimitStatus 407A LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 0
ScrData_FamilyStatus 407B Family status Device Family Status- Indicates additional status information on a device variable for a specific device family. R Enum 0
ScrData_Classification 407C Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
ScrData_Family 407D Device family Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
ScrData_USL 407E USL R Float 0
ScrData_LSL 407F LSL R Float 0
ScrData_MinSpan 4080 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
ScrData_DummyFloat 4081 Damp R Float 0
ScrData_UpdatePeriod 4082 R Time 0
ScrData_WriteDevVarCode 4083 W Enum 2052
ScrData_SerialNum 4084 R/W Unsigned 0
aim_sample_rate_op 40DF R Unsigned 2048
aim_sample_rate_var 40E0 Sample Rate variable actual value R Unsigned 2048
new_sample_rate 40E3 New Sample Rate R/W Unsigned 2048
aim_acoustic_threshold_op 40E5 R Unsigned 2048
aim_acoustic_threshold_var 40E6 Acoustic Threshold variable actual value R Unsigned 2048
new_ac_th 40E9 New Ac Th R/W Unsigned 2048
aim_lift_op 40EB R Unsigned 2048
aim_lift_var 40EC Lift totalizer actual value R Unsigned 2048
aim_dip_op 40F1 R Unsigned 2048
aim_dip_sw_var 40F2 DIP Switch SW actual value R Unsigned 2048
aim_dip_sr_var 40F4 DIP Switch SR actual value R Unsigned 2048
aim_temperature_units_op 40F9 R Unsigned 2048
aim_temperature_units_var 40FA R Unsigned 2048
aim_battery_days 40FE R/W Unsigned 0
APP_FW_MAJOR_VER 4101 Firmware Major Version R Unsigned 2048
APP_FW_MINOR_VER 4102 Firmware Minor Version R Unsigned 2048
APP_FW_REVISION_VER 4103 Firmware Revision Version R Unsigned 2048
APP_FW_BUILD_LETTER 4104 Firmware Build Letter R ASCII 2048
APP_FW_BUILD_DATE 4105 Firmware Build Date R ASCII 2048
APP_FW_BUILD_TIME 4106 Firmware Build Time R ASCII 2048
STACK_FW_MAJOR_VER 4108 Firmware Major Version R Unsigned 2048
STACK_FW_MINOR_VER 4109 Firmware Minor Version R Unsigned 2048
STACK_FW_REVISION_VER 410A Firmware Revision Version R Unsigned 2048
STACK_FW_BUILD_LETTER 410B Firmware Build Letter R ASCII 2048
device_status 0097 Device status Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process R BitEnum 131
units_code 07E9 R/W Enum 4096
transfer_function_code 07EA R/W Enum 4096
material_code 07EC R/W Enum 4096
alarm_selection_code 07EB R/W Enum 4096
write_protect_code 07EE R/W Enum 4096
company_identification_code 07EF R/W Enum 4096
physical_signaling_codes 07F1 R/W Enum 4096
flag_assignment 07F2 R/W Enum 4096
operating_mode_code 07F3 R/W Enum 4096
analog_output_numbers_code 07F4 R/W Enum 4096
loop_current_mode_codes 07F9 R/W Enum 4096
extended_device_status_codes 07FA R/W Enum 4096
lock_device_codes 07FC R/W Enum 4096