Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
cFlowRateUnits | 4000 | Flow Rate Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 8 |
rFlowRateValue | 4027 | V | TBD | R | Float | 10 |
rFlowRateUpperSensorLimit | 4028 | USL | TBD | R | Float | 8 |
rFlowRateLowerSensorLimit | 4029 | LSL | TBD | R | Float | 8 |
rFlowRateMinimumSpan | 402A | Min span | TBD | R | Float | 8 |
rFlowRateDampingValue | 402B | Damping | TBD | R | Float | 8 |
cFlowRateClassification | 402C | R | Enum | 2048 | ||
cFlowRateDataQuality | 402D | R | Integer | 10 | ||
cFlowRateLimitStatus | 402E | R | Integer | 10 | ||
cFlowRateDeviceFamilyStatus | 402F | R | Integer | 10 | ||
sensor_serial_number | 4030 | PV Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
cTotalUnits | 4031 | Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
rTotal_1Value | 4032 | Total 1 (V) | TBD | R | Float | 10 |
rTotal_2Value | 4033 | Total 2 (V2) | TBD | R | Float | 10 |
rTotal_3Value | 4034 | Total 3 (SV) | TBD | R | Float | 10 |
rUnitConvFactor | 4035 | m dim | TBD | R | Float | 8 |
rPipeDiameter | 4024 | DN | Pipe Diameter of the Tranmsitter | R/W | Float | 2048 |
rLowFlowSuppression | 4011 | LFS | Deterines the threshold value above which the flow totalizer is active.This setting is a percentage of the full-scale rate Qmax | R/W | Float | 32 |
wAverage | 4014 | Average | Determines the number of individual measurements required for the value calculation, i.e. determines the response time of the display. | R/W | Enum | 8 |
wPipeDetect | 4015 | Pipe Detect | Enables or Disables the internal Empty Pipe Detection which suppresses erroneous flow measurement caused by a partially empty flow tube. | R/W | Enum | 8 |
wOutputMode | 4016 | Output Mode | Determines the operation of the pulse outputs. | R/W | Integer | 1024 |
wCurrentMode | 401A | Current mode | Determines the electrical characteristic of the analog output. | R/W | Enum | 2048 |
wStandbyMode | 401B | Standby Mode | Reduces power consumption during metering pauses by turnin off meter coil excitation current. | R/W | Enum | 2048 |
wParMode | 400F | Parameter Mode | Security function for the parameters which allows the parameters to be protected agains unauthorized changes. | R/W | Enum | 2048 |
rQmax | 4036 | Qmax | Determines the scaling of the analog output, 100% Qmax = 20 mA. | R/W | Float | 8 |
rIMP1Pulses | 400A | pv1 | Determines the number of pulses per volume unit seen at output IMP1. Value pv1 is used when several channels are available. | R/W | Float | 512 |
rIMP2Pulses | 4012 | pv2 | Determines the number of pulses per volume unit seen at output IMP2. Only inflow is possible at Output-mode 1.5. | R/W | Float | 512 |
wIMP1OnTime | 401C | tp1 | Determines the maximum ON time duration for the pulse output IMP1. | R/W | Integer | 512 |
wIMP2OnTime | 401D | tp2 | Determines the maximum ON time duration for the pulse output IMP2. | R/W | Integer | 512 |
wIMP3OnTime | 401E | Meter Out Damp (tp3) | Damping of optional analog output 0/4-20 mA. | R/W | Integer | 512 |
wIN1Debounce | 401F | it1 | Debouncing time Minimum ON time duration required at the digital input IN1 to recognize a valid input. | R/W | Integer | 1024 |
wIN2Debounce | 4020 | it2 | Debouncing time Minimum ON time duration required at the digital input IN2 to recognize a valid input. | R/W | Integer | 1024 |
wIN3Debounce | 4021 | it3 | Debouncing time Minimum ON time duration required at the digital input IN3 to recognize a valid input. | R/W | Integer | 1024 |
wIN4Debounce | 4022 | it4 | Debouncing time Minimum ON time duration required at the digital input IN4 to recognize a valid input. | R/W | Integer | 1024 |
wQType | 4018 | Q-Typ | Determines whether the flow rate indication is displayed in units per Minute or per Hour such as gal/h or gal/min. | R/W | Enum | 8 |
wV1Format | 400D | V1 Format | Sets the number of digits displayed to the right of the decimal point for the display of the main totalizer V1. | R/W | Integer | 256 |
wV2Format | 4017 | V2 Format | Sets the number of digits displayed to the right of the decimal point for the display of the totalizer V2. | R/W | Integer | 256 |
wDecimalPoint | 4019 | Decimal Pt. | Selects period (.) or comma (,) as the display symbol for the decimal point. | R/W | Enum | 256 |
wDisplayMode | 400E | Display Mode | Determines whether the display unit is to be additionally checked (for trade use). | R/W | Enum | 256 |
rCalConstant | 4006 | m spe | Calibration factor: Factor serves to adjust the possible measuring deviations in the complete system. | R/W | Float | 8 |
rForwardConstant | 4007 | p spe | Separate Evaluation Factor for the positive flow. | R/W | Float | 8 |
rBackwardConstant | 4008 | n spe | Separate Evaluation Factor for the negative flow. | R/W | Float | 8 |
rLowFlowConstant | 4009 | b spe | Serves to adjust possible measureing deviations in the complete system for lower flow rates. | R/W | Float | 8 |
rSpanConstant | 4025 | Span | Calibration value of the transmitter. | R/W | Float | 8 |
rOffsetConstant | 4026 | Offset | Calibration value of the transmitter. | R/W | Float | 8 |
rMinVolFactor | 400B | Vmin | Smallest permissible measuring amount. | R/W | Float | 8 |
dwChecksum | 4037 | eprsum | Display of checksum of the program. | R | Integer | 2048 |
wCalChecksum | 4038 | eparasum | Display of checksum for the calibration data. | R | Integer | 2048 |
wDataChecksum | 4039 | nparasum | Display of checksum for the other data. | R | Integer | 2048 |
wSensorType | 403A | Sensor Type | Display of sensor types | R | Integer | 2048 |
Name | ID | Label | Description | Type | Access | Class |