Loading…
Name ID Label Description Type Access Class
nominal_measuring_range 4017 Nominal Measuring Range Nominal Measuring Range R Enum 2048
process_connection_type 4018 Process Connection Type Process Connection Type R Enum 2048
process_connection_material 4019 Process Connection Material Process Connection Material R Enum 2048
sensor_filling_fluid 401A Sensor Filling Fluid Sensor Filling Fluid R Enum 2048
static_pressure 401B Static Pressure Static Pressure R Enum 2048
diaphragm_seal_size 401C Diaphragm Seal Size Diaphragm Seal Size R Enum 2048
seal_diaphragm_material 401D Seal Diaphragm Material Seal Diaphragm Material R Enum 2048
seal_contact_face_material 401E Seal Contact Face Material Seal Contact Face Material R Enum 2048
seal_filling_fluid 401F Seal Filling Fluid Seal Filling Fluid R Enum 2048
nominal_pressure 4020 Nominal Pressure Nominal Pressure R Enum 2048
length_capillary_H 4021 Length Capillary H Length Capillary H R Enum 2048
length_capillary_L 4022 Length Capillary L Length Capillary L R Enum 2048
configuration_of_seal 4023 Configuration of Seal Configuration of Seal R Enum 2048
pressureValue 4024 Pres Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 10
pressureUnits 4025 Pressure unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure W Enum 0
pressureUSL 4026 Pres USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
pressureLSL 4027 Pres LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
pressureMinimumSpan 4028 Pres min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
pressureDampingValue 4029 Pres damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 0
pressureSerialNumber 402A Pres snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 2048
current_lower_trim_point 4000 Lower current trim point Lower current trim point R Float 8
current_upper_trim_point 4001 Upper current trim point Upper current trim point R Float 8
sensor_lower_trim_point 4002 Lower sensor trim point Applied process pressure at which the last low sensor trim was performed. R/W Float 8
sensor_upper_trim_point 4003 Upper sensor trim point Applied process pressure at which the last upper sensor trim was performed. R/W Float 8
current_units 4004 Current units Current units R Enum 8
Name ID Label Description Type Access Class