Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
curCmdVal | 4004 | Current Command Value | R | Float | 10 | |
curCmdUnits | 4005 | Current Command Unit | R | Enum | 8 | |
curCmdFamily | 4006 | Device family | R | Enum | 2048 | |
curCmdClassification | 4007 | Current Command Class | R | Enum | 0 | |
curCmdPDQ | 4008 | Current Command PDQ | R | Enum | 10 | |
curCmdLS | 4009 | Current Command LS | R | Enum | 10 | |
curCmdStatus | 400A | Current Command Stat | R | BitEnum | 10 | |
curCmdUSL | 400B | Current Command USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
curCmdLSL | 400C | Current Command LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
curCmdMinSpan | 400D | Current Command min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
curCmdDampingValue | 400E | Current Command Damping Value | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
curCmdUpdatePeriod | 400F | Current Command Update Period | R | Time | 0 | |
curCmdSerialNumber | 4010 | Current Command s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
curCmdSimulated | 4011 | Current Command Simulate | W | Enum | 2052 | |
fbVal | 4013 | Feedback Value | R | Float | 10 | |
fbUnits | 4014 | Feedback Unit | R | Enum | 8 | |
fbFamily | 4015 | Device family | R | Enum | 2048 | |
fbClassification | 4016 | Feedback Class | R | Enum | 0 | |
fbPDQ | 4017 | Feedback PDQ | R | Enum | 10 | |
fbLS | 4018 | Feedback LS | R | Enum | 10 | |
fbStatus | 4019 | Feedback Stat | R | BitEnum | 10 | |
fbUSL | 401A | Feedback USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
fbLSL | 401B | Feedback LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
fbMinSpan | 401C | Feedback min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
fbDampingValue | 401D | Feedback Damping Value | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
fbUpdatePeriod | 401E | Feedback Update Period | R | Time | 0 | |
fbSerialNumber | 401F | Feedback s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
fbSimulated | 4020 | Feedback Simulate | W | Enum | 2052 | |
valvePosVal | 4022 | Valve Pos Value | R | Float | 10 | |
valvePosUnits | 4023 | Valve Pos Unit | R | Enum | 8 | |
valvePosFamily | 4024 | Device family | R | Enum | 2048 | |
valvePosClassification | 4025 | Valve Pos Class | R | Enum | 0 | |
valvePosPDQ | 4026 | Valve Pos PDQ | R | Enum | 10 | |
valvePosLS | 4027 | Valve Pos LS | R | Enum | 10 | |
valvePosStatus | 4028 | Valve Pos Stat | R | BitEnum | 10 | |
valvePosUSL | 4029 | Valve Pos USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
valvePosLSL | 402A | Vave Pos LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
valvePosMinSpan | 402B | Valve Pos min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
valvePosDampingValue | 402C | Valve Pos Damping Value | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 0 |
valvePosUpdatePeriod | 402D | Valve Pos Update Period | R | Time | 0 | |
valvePosSerialNumber | 402E | Valve Pos s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
valvePosSimulated | 402F | Valve Pos Simulate | W | Enum | 2052 | |
inputCurVal | 4031 | HART 4-20mA Input Cur | R | Float | 10 | |
inputCurUnits | 4032 | HART 4-20mA Input Cur Unit | R | Enum | 8 | |
inputCurFamily | 4033 | Device family | R | Enum | 2048 | |
inputCurClassification | 4034 | HART 4-20mA Input Cur Class | R | Enum | 0 | |
inputCurPDQ | 4035 | HART 4-20mA Input Cur PDQ | R | Enum | 10 | |
inputCurLS | 4036 | HART 4-20mA Input Cur LS | R | Enum | 10 | |
inputCurStatus | 4037 | HART 4-20mA Input Cur Stat | R | BitEnum | 10 | |
inputCurUSL | 4038 | HART 4-20mA Input Cur USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
Name | ID | Label | Description | Type | Access | Class |