Name ID Label Description Type Access Class
ssnCommon 400A Snsr s/n Número de série do sensor – Unicamente indentifica o sensor do qual a representação de valor digital ou variável do dispositivo de campo é primariamente derivada. R/W Unsigned 8
dunLength 400B Unit Length Unit for Length values. R/W Enum 8
dfoSensorValue 400D Format Sensor Value Display format for Sensor Value. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlSensorValue 400C Sensor Value Sensor Value after device calibration is applied but without any additional offsets. R/W Float 10
uslSensorValue 4010 Upper Sensor Limit Valor do limite do sensor superior- Define o valor máimo usável para o valor de faixa superior. R Float 8
lslSensorValue 4011 Lower Sensor Limit Valor do limite do sensor inferior- Define o valor máimo usável para o valor de faixa inferior. R Float 8
mspSensorValue 4012 Minimum Span Valor de intervalo mínimo- Define a menor diferença permitida entre o valor de faixa superior e o valor de faixa inferior. R Float 8
clsSensorValue 4013 Unit Class Sensor Value Device Variable Class. Defines also the set of selectable physical units. R Enum 8
dfaSensorValue 4014 Family Device Variable Family R Enum 8
dqaSensorValue 4015 Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstSensorValue 4016 Limit Status Limit Status 'LS' R/W Enum 10
fstSensorValue 4017 Family Status Family Status 'FS' R BitEnum 10
utpSensorValue 4018 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulateSensorValue 4019 Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
propertiesSensorValue 401A Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dfoMediaLevel 401D Format Media Level Display format for Media Level. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlMediaLevel 401C Media Level Media Level after offsets are applied. R/W Float 10
uslMediaLevel 401E Upper Sensor Limit Valor do limite do sensor superior- Define o valor máimo usável para o valor de faixa superior. R Float 8
lslMediaLevel 401F Lower Sensor Limit Valor do limite do sensor inferior- Define o valor máimo usável para o valor de faixa inferior. R Float 8
mspMediaLevel 4020 Minimum Span Valor de intervalo mínimo- Define a menor diferença permitida entre o valor de faixa superior e o valor de faixa inferior. R Float 8
dfaMediaLevel 4021 Family Device Variable Family R Enum 8
dqaMediaLevel 4022 Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstMediaLevel 4023 Limit Status Limit Status 'LS' R/W Enum 10
fstMediaLevel 4024 Family Status Family Status 'FS' R BitEnum 10
utpMediaLevel 4025 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8