Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
compat_burst_mode_0 | 40EB | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | R/W | Enum | 128 |
compat_burst_trig_mode_0 | 40EC | Trigger Mode | Selects the Burst Trigger Mode. Burst messages may be configured to publish continuously or based on a Trigger Level. | R/W | Enum | 128 |
compat_burst_trig_class_0 | 40ED | Classification | The classification of the burst trigger variable | R/W | Enum | 16 |
compat_burst_trig_units_0 | 40EE | Unit | The unit of the burst trigger variable | R/W | Enum | 16 |
compat_burst_vars_0_1 | 4103 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_1_1 | 4104 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_2_1 | 4105 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_3_1 | 4106 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_4_1 | 4107 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_5_1 | 4108 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_6_1 | 4109 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_7_1 | 410A | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_update_per_1 | 40FC | Update Period | Update period for the burst message in seconds when the burst trigger conditions are met. Allowed Values: 0.5, 1, 2, 4, 8, 16, 32, 60-3600. | R/W | Time | 2048 |
compat_max_update_per_1 | 40FD | Max Update Period | Update period for the burst message in seconds when the burst trigger conditions are not met. Allowed Values: 0.5, 1, 2, 4, 8, 16, 32, 60-3600. | R/W | Time | 2048 |
compat_burst_cmd_1 | 40FB | Command | Command message that is transmitted for the respective burst message by the device while in burst mode. | R/W | Enum | 128 |
compat_burst_trig_level_1 | 4102 | Burst Trigger Level | The Burst Trigger level defines the threshold that must be exceeded to start bursting. | R/W | Float | 2048 |
compat_burst_mode_1 | 40FE | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | R/W | Enum | 128 |
compat_burst_trig_mode_1 | 40FF | Trigger Mode | Selects the Burst Trigger Mode. Burst messages may be configured to publish continuously or based on a Trigger Level. | R/W | Enum | 128 |
compat_burst_trig_class_1 | 4100 | Classification | The classification of the burst trigger variable | R/W | Enum | 16 |
compat_burst_trig_units_1 | 4101 | Unit | The unit of the burst trigger variable | R/W | Enum | 16 |
compat_burst_vars_0_2 | 4116 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_1_2 | 4117 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_2_2 | 4118 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_3_2 | 4119 | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_4_2 | 411A | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_5_2 | 411B | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_6_2 | 411C | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_burst_vars_7_2 | 411D | Burst Variable Code | Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. | R/W | Index | 2048 |
compat_update_per_2 | 410F | Update Period | Update period for the burst message in seconds when the burst trigger conditions are met. Allowed Values: 0.5, 1, 2, 4, 8, 16, 32, 60-3600. | R/W | Time | 2048 |
compat_max_update_per_2 | 4110 | Max Update Period | Update period for the burst message in seconds when the burst trigger conditions are not met. Allowed Values: 0.5, 1, 2, 4, 8, 16, 32, 60-3600. | R/W | Time | 2048 |
compat_burst_cmd_2 | 410E | Command | Command message that is transmitted for the respective burst message by the device while in burst mode. | R/W | Enum | 128 |
compat_burst_trig_level_2 | 4115 | Burst Trigger Level | The Burst Trigger level defines the threshold that must be exceeded to start bursting. | R/W | Float | 2048 |
compat_burst_mode_2 | 4111 | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | R/W | Enum | 128 |
compat_burst_trig_mode_2 | 4112 | Trigger Mode | Selects the Burst Trigger Mode. Burst messages may be configured to publish continuously or based on a Trigger Level. | R/W | Enum | 128 |
compat_burst_trig_class_2 | 4113 | Classification | The classification of the burst trigger variable | R/W | Enum | 16 |
compat_burst_trig_units_2 | 4114 | Unit | The unit of the burst trigger variable | R/W | Enum | 16 |
loc_upperRange_value | 4354 | PV URV | Valor de rango superior: Define el punto final de funcionamiento del cual se derivan el valor analógico y el punto 100% del rango de porcentaje. Además, el valor de rango superior define un punto final de funcionamiento del que se derivan las alarmas asociadas con el valor analógico y las alarmas asociadas con la representación del valor digital. | R/W | Float | 4096 |
bkp_upperRange_value | 436D | PV URV | Valor de rango superior: Define el punto final de funcionamiento del cual se derivan el valor analógico y el punto 100% del rango de porcentaje. Además, el valor de rango superior define un punto final de funcionamiento del que se derivan las alarmas asociadas con el valor analógico y las alarmas asociadas con la representación del valor digital. | R/W | Float | 4096 |
loc_OptionRangeOutputCurrentA | 4356 | Current Out. Range | Select the output range (Fct. C4.1.4) | R/W | Enum | 4096 |
bkp_OptionRangeOutputCurrentA | 436E | Current Out. Range | Select the output range (Fct. C4.1.4) | R/W | Enum | 4096 |
loc_OptionSignalAlarmOutputCurrentA | 4357 | Error Function | Specify error current. (Fct. C4.1.5) | R/W | Enum | 4096 |
bkp_OptionSignalAlarmOutputCurrentA | 436F | Error Function | Specify error current. (Fct. C4.1.5) | R/W | Enum | 4096 |
loc_ErrorDelayOutputCurrentA | 4358 | Error Delay | Delay between error detection and set of error output (Fct. C4.1.6) | R/W | Enum | 4096 |
bkp_ErrorDelayOutputCurrentA | 4370 | Error Delay | Delay between error detection and set of error output (Fct. C4.1.6) | R/W | Enum | 4096 |
loc_lowerRange_value | 4355 | PV LRV | Valor de rango inferior: Define el punto final de funcionamiento del que se derivan el valor analógico, y el punto 0% del rango de porcentaje. Además, el valor de rango inferior define un punto final de funcionamiento del que se derivan las alarmas asociadas al valor analógico y las alarmas asociadas a la representación del valor digital. | R/W | Float | 4096 |
bkp_lowerRange_value | 4371 | PV LRV | Valor de rango inferior: Define el punto final de funcionamiento del que se derivan el valor analógico, y el punto 0% del rango de porcentaje. Además, el valor de rango inferior define un punto final de funcionamiento del que se derivan las alarmas asociadas al valor analógico y las alarmas asociadas a la representación del valor digital. | R/W | Float | 4096 |
loc_OptionMeasurementOutputCurrentA | 4359 | Current Out. 1 Var. | Select the current output variable (Fct. C4.1.1, C5.1.4.1) | R/W | Enum | 4096 |
bkp_OptionMeasurementOutputCurrentA | 4372 | Current Out. 1 Var. | Select the current output variable (Fct. C4.1.1, C5.1.4.1) | R/W | Enum | 4096 |
loc_Range0PctMeasurementOutputCurrentB | 435A | 0% Range | (Fct. C4.2.2) | R/W | Float | 4096 |
bkp_Range0PctMeasurementOutputCurrentB | 4373 | 0% Range | (Fct. C4.2.2) | R/W | Float | 4096 |
Name | ID | Label | Description | Type | Access | Class |