Name ID Label Description Type Access Class
process_data_status 0804 R/W Enum 4096
limit_status 0805 R/W Enum 4096
device_family_status 0806 R/W Enum 4096
country_code_codes 08D3 R/W Enum 4096
device_power_status_codes 08D4 R/W Enum 4096
master_mode_code 08D5 R/W Enum 4096
device_status 0097 Device Status Shows the current Device Status R BitEnum 131
write_protect 00A7 Write Protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R Enum 2048
physical_signaling_code 00AB Physicl signl code Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port R Enum 2048
operatingMode 0870 Operate mode 1 Field Device Specific Operating Mode 1- A possible mode of operation in Field Device R Enum 2049
loop_current_mode 0808 Loop current mode Modo de corriente de lazo: Indica si la corriente de lazo es activa o fija (es decir, el dispositivo está en derivaciones múltiples). R/W Enum 64
device_flags 00A0 Dev flags Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer R BitEnum 2048
extended_fld_device_status 0807 Ext. Device Status Provides additional Device Status informations R BitEnum 131
device_profile 00FF Device Profile R Enum 2048
standardized_status_0 0104 Device Diagnostic Status 0 Status commonly used in a wide range of devices and device types R BitEnum 131
standardized_status_1 0105 Device Diagnostic Status 1 Status commonly used in a wide range of devices and device types R BitEnum 131
standardized_status_2 0106 I/O and Subdevice Status R BitEnum 131
standardized_status_3 0107 WirelessHART Status R BitEnum 131
analog_channel_saturated1 103D AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 2051
analog_channel_fixed1 1040 AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 2051
time_set 1157 Time Set Option W Enum 2052
real_time_clock_flag 115C Real Time Clock Flags R BitEnum 2050
country_code 1259 Country Country of intended device installation R/W Enum 2048
si_control 125A SI Unit Control Indicates if device should only display SI unit codes R/W Enum 2048
burst_trigger_units 1267 Burst Trigger Units R/W Enum 16
burst_trigger_classification 1266 Burst Trigger Class R/W Enum 16
burst_mode_select 0FFF Burst mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. R/W Enum 128
burst_message_trigger_mode 08D8 Burst Msg Trigger Mode R/W Enum 128
event_status 08D9 Event Status R BitEnum 130
event_notification_control_n 08DA Event Notification Control R/W Enum 128
dev_operating_mode_mask 08F9 Operate mode Mask R/W BitEnum 2048
lock_device_code 106F Lock dev code Código de bloqueo del dispositivo: Indica si el dispositivo se ha colocado en posición de bloqueo para evitar que se hagan cambios manualmente o desde otro maestro. W Enum 2048
lock_device_status_code 1070 Lock Status Shows the current lock state of the device. Device is locked: Device is locked and the configuration can only be unlocked by the host that activates the lock. Lock is permanent: Device lock will sustain a device restart / reset Locked by primary Master: Device is locked by a primary master. Only a primary Master can unlock the device. Locked for All: Device is locked for all masters. Any master can unlock the device. R BitEnum 2048
power_source 36CC Power Source Power source of the device R Enum 128
wireless_mode 36BB Wireless Mode R Enum 2050
join_status 36BC Join Status The current location in the joining sequence of operations. R BitEnum 2050
network_access_mode 36E4 Network Access Mode R/W Enum 128
join_mode 36C3 Join Mode R/W Enum 128
device_power_status 36DB Power Status Power status of the device R Enum 2050
master_mode 1091 Master Mode This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. R/W Enum 128
trend_digital_units 1166 Trend Units Trend Device Variable Unit Code R Enum 2052
trend_classification 1165 Trend Classification Trend Device Variable Classification R Enum 2052
trend_control 1163 Trend Control R/W Enum 132
manufacturer_id 0099 Fabricante Código de identificación del fabricante: Hace referencia a un fabricante específico y suele ser el nombre de la empresa responsable de la fabricación de este dispositivo de campo. R Enum 128
private_label_distributor 00A8 Distribuidor Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 2048
device_type 009A Model Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer R Enum 128
device_status_mask 08DB Device Status Mask R/W BitEnum 2048
extended_fld_device_status_mask 08DC Ext dev status Mask R/W BitEnum 2048
standardized_status_0_mask 08DD Device Diagnostic Status 0 Mask R/W BitEnum 2048
standardized_status_1_mask 08DE Device Diagnostic Status 1 Mask R/W BitEnum 2048
Name ID Label Description Type Access Class