Loading…
Name ID Label Description Type Access Class
aunTV 40B9 AO unit R Enum 64
avlTV 40B8 TV output value TV output value R/W Float 66
acdTV 40BA AO Alrm typ R Enum 64
uepTV 40BB AO hi end pt Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
lepTV 40BC AO lo end pt Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions R Float 64
ulvTV 40BD Upper Limit Value The maximum value of the analog signal. R Float 64
llvTV 40BE Lower Limit Value The minimum value of the analog signal. R Float 64
adpTV 40BF Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R Float 64
acfTV 40C0 Channel flags Analog Channel Flags- Defines the characteristics of the Analog Channel R BitEnum 64
pcrQV 40C3 QV % range Percent of range of the HART Secondary Variable (SV); tracks the associated measured value with respect to the Lower Range Value and Upper Range Value. R Float 34
Name ID Label Description Type Access Class