Loading…
Name ID Label Description Type Access Class
difference_s1_s2_digital_units 4062 Unit Unit for Difference Measurement (Sensor 1 - Sensor 2) and for all other relevant device variables R/W Enum 0
difference_s1_s2_digital_value 4063 Difference: Sensor 1 - Sensor 2 Unidade de variável do dispositivo de campo- Unidade de engenharia para ser apresentada com a representação do valor digital, intervalo mínimo, valor da faixa superior, valor da faixa inferior, limite do sensor inferior, e limite do sensor superior R Float 2
damping_value_DiffS1S2 40DC Damping Damping time constant applied to both the Digital Value representation and Analog Value of a respective Analog Output. The units of this variable are always in seconds R/W Float 0
difference_s1_s2_upper_sensor_limit 4064 UpperLimit Valor do limite do sensor superior- Define o valor máimo usável para o valor de faixa superior. R Float 0
difference_s1_s2_lower_sensor_limit 4065 Lower Limit Valor do limite do sensor inferior- Define o valor máimo usável para o valor de faixa inferior. R Float 0
difference_s1_s2_minimum_span 4066 Min Span Valor de intervalo mínimo- Define a menor diferença permitida entre o valor de faixa superior e o valor de faixa inferior. R Float 0
snr1snr2qty 40DD Snr1-Snr2 Status Qualidade do dado do processo- Indica a qualidade do dado do processo todp do valor da variável do dispositivo. R Enum 2
difference_s2_s1_digital_units 4068 Unit Unit for Difference Measurement (Sensor 2 - Sensor 1) and for all other relevant device variables R/W Enum 0
difference_s2_s1_digital_value 4069 Difference: Sensor 2 - Sensor 1 Differential Measurement is derived by computing the difference between Sensor 1 and Sensor 2 (Sensor 2 - Sensor 1). Both sensors should be configured. R Float 2
damping_value_DiffS2S1 40DE Damping Damping time constant applied to both the Digital Value representation and Analog Value of a respective Analog Output. The units of this variable are always in seconds R/W Float 0
Name ID Label Description Type Access Class