Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
difference_s1_s2_digital_units | 4062 | Unit | Unit for Difference Measurement (Sensor 1 - Sensor 2) and for all other relevant device variables | R/W | Enum | 0 |
difference_s1_s2_digital_value | 4063 | Difference: Sensor 1 - Sensor 2 | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Float | 2 |
damping_value_DiffS1S2 | 40DC | Damping | Damping time constant applied to both the Digital Value representation and Analog Value of a respective Analog Output. The units of this variable are always in seconds | R/W | Float | 0 |
difference_s1_s2_upper_sensor_limit | 4064 | UpperLimit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
difference_s1_s2_lower_sensor_limit | 4065 | Lower Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
difference_s1_s2_minimum_span | 4066 | Min Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
snr1snr2qty | 40DD | Snr1-Snr2 Status | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
difference_s2_s1_digital_units | 4068 | Unit | Unit for Difference Measurement (Sensor 2 - Sensor 1) and for all other relevant device variables | R/W | Enum | 0 |
difference_s2_s1_digital_value | 4069 | Difference: Sensor 2 - Sensor 1 | Differential Measurement is derived by computing the difference between Sensor 1 and Sensor 2 (Sensor 2 - Sensor 1). Both sensors should be configured. | R | Float | 2 |
damping_value_DiffS2S1 | 40DE | Damping | Damping time constant applied to both the Digital Value representation and Analog Value of a respective Analog Output. The units of this variable are always in seconds | R/W | Float | 0 |
difference_s2_s1_upper_sensor_limit | 406A | UpperLimit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
difference_s2_s1_lower_sensor_limit | 406B | Lower Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
difference_s2_s1_minimum_span | 406C | Min Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
snr2snr1qty | 40DF | Snr2-Snr1 Status | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
average_digital_units | 406E | Unit | Unit for Sensor Averaging measurement of both Sensors and for all other relevant device variables | R/W | Enum | 0 |
average_digital_value | 406F | Average Sensor 1 and Sensor 2 | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 2 |
damping_value_average | 40E0 | Damping | Damping time constant applied to both the Digital Value representation and Analog Value of a respective Analog Output. The units of this variable are always in seconds | R/W | Float | 0 |
average_upper_sensor_limit | 4070 | UpperLimit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
average_lower_sensor_limit | 4071 | Lower Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
average_minimum_span | 4072 | Min Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
avgqty | 40E1 | Avg Value Status | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2 |
redundant_digital_units | 4074 | Redundancy sensor 1 / sensor 2 | Sensor 1 is the guide (primary) Sensor. In case of defective Sensor 1, PV (Redundany Option availibility) takes value of sensor 2. Make sure both sensors are configured. | R/W | Enum | 0 |
redundant_digital_value | 4075 | Redundancy sensor 1 / sensor 2 | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 2 |
damping_value_redundancy | 40E2 | Damping | Damping time constant applied to both the Digital Value representation and Analog Value of a respective Analog Output. The units of this variable are always in seconds | R/W | Float | 0 |
redundant_upper_sensor_limit | 4076 | Upper Limit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
Name | ID | Label | Description | Type | Access | Class |