Loading…
Name ID Label Description Type Access Class
range_units 4042 Range unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 36
sensor1_digital_units 4043 Snsr1 Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 36
sensor1_digital_value 4044 Snsr1 Sensor of channel 1 R Float 34
sensor1_upper_sensor_limit 401B Snsr1 Upr Lmt Valore limite sensore superiore - Definisce il valore massimo utilizzabile per il valore di campo superiore. R Float 8
sensor1_lower_sensor_limit 401A Snsr1 Lor Lmt Valore limite sensore inferiore - Definisce il valore minimo utilizzabile per il valore di campo inferiore. R Float 8
sensor1_minimum_span 401C Snsr1 Min Span Valore intervallo minimo - Definisce la differenza più piccola consentita tra il valore di campo superiore e il valore di campo inferiore. R Float 12
sensor2_digital_units 404A Snsr2 Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 36
sensor2_digital_value 404B Snsr2 Sensor of channel 2 R Float 34
sensor2_upper_sensor_limit 402A Snsr2 Upr Lmt Valore limite sensore superiore - Definisce il valore massimo utilizzabile per il valore di campo superiore. R Float 8
sensor2_lower_sensor_limit 4029 Snsr2 Lor Lmt Valore limite sensore inferiore - Definisce il valore minimo utilizzabile per il valore di campo inferiore. R Float 8
Name ID Label Description Type Access Class