名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
messart | 4000 | 测量类型 | Type of measurement - Setting of vital input parameters on transmitter. | 读/写 | 枚举 | 2048 |
sensor_typ | 4003 | 传感器类型 | Sensor type - Type of currently connected sensor. Depending on the type of selected characteristic line, the measured value is influenced. | 读/写 | 枚举 | 8 |
wire_no | 4001 | Sensor connection | Sensor connection - States the number of wires, via which the sensor is connected to the transmitter. | 读/写 | 枚举 | 8 |
n_sensor | 4002 | Number of sensors | Number of sensors - States the number of sensors which areconnected in series at every input. A multiple number of the built-in characteristic lines can be realised (e.g. 10*Pt100 = Pt1000). | 读/写 | 枚举 | 8 |
sensor_monitor | 4004 | Sensor monitoring | Sensor monitoring - With this setting the monitoring of the sensors can be limited or released. An internal reference junction is always monitored. | 读/写 | 枚举 | 8 |
refer_junction | 4006 | ext. ref. junction | External reference junction - The value states the temperature of the external reference junction. The input is always made in °C! | 读/写 | 浮点 | 8 |
out_select | 4009 | 输出 | Analog output - The device is only available as signal output 4..20mA. An under- or overrange exceeding this range is however possible. | 读/写 | 枚举 | 2048 |
out_under | 400A | Underrange value | Underrange value - The control range is limited by the underrange value. In case of failure signal, the value is also accepted by means of underranging. | 读/写 | 浮点 | 8 |
out_over | 400B | Overrange value | Overrange value - The control range is limited by the overrange value. In case of failure signal, the value is also accepted by means of overranging. | 读/写 | 浮点 | 8 |
alter_selector | 4005 | Failure signalling | Failure signalling - The setting indicates the strategy for signalling a failure. | 读/写 | 枚举 | 8 |
alter_value | 400C | Default value | Default value - in case of failure, the analog output is set on the programmed value if the matching error strategy was selected. | 读/写 | 浮点 | 8 |
sensor_name | 400F | Sensor name | Sensor name - The function permits the input of a sensor name when using user defined characteristics. | 读/写 | 压缩文本 | 8 |
order_no | 4010 | Catalog number | Catalog number - The function permits the changing of the catalog number after entering changes on transmitter. | 读/写 | 压缩文本 | 2048 |
kanal | 4013 | Signal input | Signal input - The setting determines the signal input which must be balanced. | 写 | 无符号 | 8 |
sollwert | 4014 | 设定点 | Set point - The value states the (e.g. simulated via a reference) input signal. | 写 | 浮点 | 8 |
_input_range | 402F | Input assignment | Input assignment - measuring range of the transmitter at the input. | 写 | 枚举 | 4096 |
_type_of_refer_junc | 4030 | Reference junction | Reference junction - The setting determines the type of reference junction during measurements with thermocouples. Always select 'WITHOUT' for measurements witout thermocouples. | 写 | 枚举 | 4096 |
_sensor_monitor | 4031 | Sensor monitoring | Sensor monitoring - With this setting the monitoring of the sensors can be limited or released. An internal reference junction is always monitored. | 写 | 枚举 | 4096 |
_failure_control | 4035 | Failure monitoring | Failure monitoring - The setting determines if the analog output should react to certain failure states in the transmitter. | 读/写 | 枚举 | 4096 |
_failure_signal | 4036 | Signalling | Signalling - The setting determines if a failure shall be signalled via the analog output. | 读/写 | 枚举 | 4096 |
_version | 4039 | Version 1.00 | 读 | 枚举 | 4096 | |
digital_units | 4017 | 单位 | 现场设备变量单位——使用数值表示、最小范围、范围上限、范围下限、传感器上限和传感器下限显示的工程单位。 | 读/写 | 枚举 | 32 |
primary_measurement_digital_value | 4018 | Measured value | Measured value - Measured value that changes magnitude with respect to time with no user intervention. | 读 | 浮点 | 34 |
primary_measurement_percent_range | 403E | Measured value | Percent of range - Digital value that is proportional to the variable DIGITAL_VALUE with respect to the range defined by the LOWER_RANGE_VALUE and UPPER_RANGE_VALUE. The units of this variable are always in percent. | 读 | 浮点 | 34 |
analog_output_transfer_function | 403F | 转换功能 | 传送功能——定义由现场设备变量应用至模拟量输出和百分比范围的传送功能。传送功能不影响数值表示。 | 读 | 枚举 | 32 |
primary_measurement_upper_range_value | 4019 | URV | Upper range value - Defines the operational endpoint from which the variables ANALOG_VALUE, PERCENT_RANGE are derived. | 读/写 | 浮点 | 32 |
primary_measurement_lower_range_value | 401A | LRV | Lower range value - Defines the operational endpoint from which the variables ANALOG_VALUE, PERCENT_RANGE are derived. | 读/写 | 浮点 | 32 |
primary_measurement_damping_value | 4027 | 阻尼 | Damping value - Damping time applied to both the variables DIGITAL_VALUE and ANALOG_VALUE of output 'X'. The units of this variable are always expressed in seconds. | 读/写 | 浮点 | 32 |
sensor_serial_number | 4040 | 传感器序列号 | 传感器序列号——识别数值表示或现场设备变量来源的传感器。 | 读/写 | 无符号 | 2048 |
primary_measurement_upper_sensor_limit | 401B | USL | Upper sensor limit value - Value that defines the absolute upper endpoint (largest magnitude) for the UPPER RANGE VALUE. | 读 | 浮点 | 8 |
primary_measurement_lower_sensor_limit | 401C | LSL | Lower sensor limit value - Value that defines the absolute lower endpoint (smallest magnitude) for the LOWER RANGE VALUE. | 读 | 浮点 | 8 |
primary_measurement_minimum_span | 401D | 最小范围 | Minimum span value - Value that defines the smallest absolute value for the resulting figure derived from the following equation (UPPER RANGE VALUE - LOWER RANGE VALUE). | 读 | 浮点 | 8 |
ma_analog_output_value | 4041 | 模拟量输出 | 模拟量输出——在没有用户干扰的情况下,根据时间变化的可测量物理输出。 | 读/写 | 浮点 | 66 |
ma_analog_output_alarm_select | 4042 | Alarm type | 模拟量输出报警类型——定义当现场设备检测到模拟量输出可能未跟踪关联现场设备变量时模拟量输出响应的方式。注意——数值表示可能不确定。 | 读 | 枚举 | 64 |
electronics_temperature_digital_units | 4025 | CJC温度单位 | Temp. unit of the reference junction temperature - The temperature on the terminal block of the field unit is always stated in °C during measurements with internal or external reference junction. | 读 | 枚举 | 34 |
electronics_temperature_digital_value | 4008 | CJC温度 | Reference junction temperature value - Temperature associated with the internal/external reference junction. At an internal reference junction the temperature of the connection terminals of the transmitter will be measured during measurements. | 读/写 | 浮点 | 34 |
sensor1_digital_units | 401F | 单位 | Unit - physical unit in which the electrical value of the sensor is expressed. | 读 | 枚举 | 34 |
sensor1_measurement_digital_value | 4020 | 传感器1 | Sensor value - electrical value of the sensor at the input. | 读 | 浮点 | 34 |
sensor2_digital_units | 4022 | 单位 | Unit - physical unit in which the electrical value of the sensor is expressed. | 读 | 枚举 | 34 |
sensor2_measurement_digital_value | 4023 | 传感器2 | Sensor value - electrical value of the sensor at the auxiliary input. | 读 | 浮点 | 34 |
units_code | 07E9 | 读/写 | 枚举 | 4096 | ||
transfer_function_code | 07EA | 读/写 | 枚举 | 4096 | ||
alarm_selection_code | 07EB | 读/写 | 枚举 | 4096 | ||
write_protect_code | 07EE | 读/写 | 枚举 | 2048 | ||
company_identification_code | 07EF | 读/写 | 枚举 | 128 | ||
flag_assignment | 07F2 | 读/写 | 枚举 | 128 | ||
operating_mode_code | 07F3 | 读/写 | 枚举 | 2048 | ||
response_code | 0096 | 特定命令响应代码——现场设备响应返回的数据,表示主机请求命令发送成功。该信息可能与主机请求数据或命令本身有关。 | 读/写 | 枚举 | 129 | |
comm_status | 0098 | 通讯错误汇总——现场设备在尝试接收主机请求时检测到下列错误条件。因此命令未被接受,并且主机请求在现场设备上未引起变化。 | 读/写 | 位枚举 | 131 | |
device_status | 0097 | 现场设备状态——表示现场设备已检测到有关硬件/变量有效性/操作状态/内部过程的条件的数据。 | 读/写 | 位枚举 | 131 | |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |