primary_measurement_lower_range_value 401E LRV Lower range value - Defines the operational endpoint from which the variables ANALOG_VALUE, PERCENT_RANGE are derived. R/W Float 32
primary_measurement_damping_value 4098 Damp Damping value - Damping time applied to both the variables DIGITAL_VALUE and ANALOG_VALUE of output 'X'. The units of this variable are always expressed in seconds. R/W Float 32
sensor_serial_number 4099 Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 2048
primary_measurement_upper_sensor_limit 401F USL Upper sensor limit value - Value that defines the absolute upper endpoint (largest magnitude) for the UPPER RANGE VALUE. R Float 8
primary_measurement_lower_sensor_limit 4020 LSL Lower sensor limit value - Value that defines the absolute lower endpoint (smallest magnitude) for the LOWER RANGE VALUE. R Float 8
primary_measurement_minimum_span 4021 Min span Minimum span value - Value that defines the smallest absolute value for the resulting figure derived from the following equation (UPPER RANGE VALUE - LOWER RANGE VALUE). R Float 8
ma_analog_output_value 409A AO Analog Output- Measurable physical output which changes with respect to time, without user intervention R/W Float 66
ma_analog_output_alarm_select 409B Alarm type Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
electronics_temperature_digital_units 4029 CJC temp unit Temp. unit of the reference junction temperature - The temperature on the terminal block of the field unit is always stated in °C during measurements with internal or external reference junction. R Enum 34
electronics_temperature_digital_value 402A CJC temp Reference junction temperature value - Temperature associated with the internal/external reference junction. At an internal reference junction the temperature of the connection terminals of the transmitter will be measured during measurements. R/W Float 34
sensor1_digital_units 4023 Unit Unit - physical unit in which the electrical value of the sensor is expressed. R Enum 34
sensor1_measurement_digital_value 4024 Snsr1 Sensor value - electrical value of the sensor at the input. R Float 34
sensor2_digital_units 4026 Unit Unit - physical unit in which the electrical value of the sensor is expressed. R Enum 34
sensor2_measurement_digital_value 4027 Snsr2 Sensor value - electrical value of the sensor at the auxiliary input. R Float 34
units_code 07E9 R/W Enum 4096
transfer_function_code 07EA R/W Enum 4096
alarm_selection_code 07EB R/W Enum 4096
write_protect_code 07EE R/W Enum 2048
company_identification_code 07EF R/W Enum 128
flag_assignment 07F2 R/W Enum 128
operating_mode_code 07F3 R/W Enum 2048
response_code 0096 Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. R/W Enum 129
comm_status 0098 Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. R/W BitEnum 131
device_status 0097 Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process R/W BitEnum 131
manufacturer_id 0099 Manufacturer Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device. R Enum 128
device_type 009A Model Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer R Enum 128
request_preambles 009B Num req preams Number of Request Preambles- Number of Preambles required from the Host request by the Field Device R Unsigned 128
universal_revision 009C Universal rev Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to R Unsigned 128
transmitter_revision 009D Fld dev rev Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to R Unsigned 128
software_revision 009E Software rev Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device R Unsigned 2048
hardware_revision 009F Hardware rev Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device. R Unsigned 2048
physical_signaling_code 00AB Physicl signl code Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port R Enum 2048
device_flags 00A0 Dev flags Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer R BitEnum 128
device_id 00A1 Dev id Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. R Unsigned 128
polling_address 00A2 Poll addr Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) W Unsigned 128
tag 00A3 Tag Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. R/W PackedAscii 2048
message 00A4 Message Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. R/W PackedAscii 2048
descriptor 00A5 Descriptor Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. R/W PackedAscii 2048
date 00A6 Date Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. R/W HartDate 2048
write_protect 00A7 Write protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R Enum 2048
private_label_distributor 00A8 Distributor Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 2048
final_assembly_number 00A9 Final asmbly num Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. R/W Unsigned 2048
eeprom_select 0FAB EEPROM select Electrically Erasable Read Only Memory Selection- Controls the data in: EEPROM Read Only Memory / Read Only Memory. R/W Enum 4096
xmtr_specific_status_0 0FB5 Memory status Memory failure - The instrument error can possibly be remedied through self-test correction. If it continues to exist, it means the unit is defective. R BitEnum 2051
xmtr_specific_status_1 0FB6 Status group 2 Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
xmtr_specific_status_2 0FB7 Input status Input failures - in the measurement electronic are limit value infringements. If the unit is being operated under permissible ambient conditions, the unit is defective. R BitEnum 2051
xmtr_specific_status_3 0FB8 Balancing/Parameter Balancing/Parameter - The error status of the balancing and configuration data can be read out. R BitEnum 2051
xmtr_specific_status_4 0FB9 Sensor status Sensor status - The status of the active sensors can be read out. R BitEnum 2051
xmtr_specific_status_5 0FBA Output status Output status - The status of the analog output can be read out. R BitEnum 2051
response_preambles 0FE2 Num resp preams Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host W Unsigned 128