Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
var_TB82_user_defined_conc_x6 | 401E | x6 Cond | x6 Conductivity point of the user defined concentration curve. | R/W | Float | 8 |
var_TB82_user_defined_conc_y1 | 4015 | y1 Concen | y1 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y2 | 4017 | y2 Concen | y2 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y3 | 4019 | y3 Concen | y3 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y4 | 401B | y4 Concen | y4 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y5 | 401D | y5 Concen | y5 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y6 | 401F | y6 Concen | y6 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_lcd_secondary | 402C | LCD secondry disp | The parameter sets the HMI's local LCD secondary display area to one of several options. | R/W | Enum | 256 |
var_TB82_security_lock | 402D | Security Lock | When ENABLED, the Security Password will be active for Security mode on local HMI. If Security Lock is disabled, then the Security mode of operation can be accessed from the local HMI without supplying the password. | R/W | Enum | 2048 |
var_TB82_configuration_lock | 402E | Configuration Lock | When ENABLED, the Security Password will be active for Config mode on local HMI. Config parameters will be write protected on the HART interface. When the Configuration-Lock is DISABLED, the Config mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_calibration_lock | 402F | Calibration Lock | When ENABLED, the Security Password will be active for Calibrate mode on local HMI. Calib parameters will be write protected on the HART interface. When the Calibration Lock is DISABLED, the Calibrate mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_output_lock | 4030 | Output Lock | When ENABLED, the Security Password will be active for Output mode on local HMI. Output related parameters will be write protected on the HART interface. When the Output Lock is DISABLED, the Output mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_password_digit_1 | 407E | Secur. Passwrd 1 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_password_digit_2 | 407F | Secur. Passwrd 2 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_password_digit_3 | 4080 | Secur. Passwrd 3 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_pv_slope_units | 4060 | PV slope units | R/W | Enum | 8 | |
var_TB82_pv_slope | 4028 | PV Steilheit | PV Sensor-Steilheit in Prozent | R/W | Float | 8 |
var_TB82_pv_offset_units | 4044 | PV snsr offset unit | PV sensor offset unit | R/W | Enum | 8 |
var_TB82_pv_offset | 4029 | PV offset | PV Sensor Nullpunktverschiebung | R/W | Float | 8 |
var_TB82_temp_slope_units | 4063 | Temp slope units | R/W | Enum | 8 | |
var_TB82_temp_slope | 402A | Temperatursensor Steigung | Temperatursensor Steigung | R/W | Float | 8 |
var_TB82_temp_offset_units | 4046 | Temp snsr offset unit | Temperature sensor offset unit | R/W | Enum | 8 |
var_TB82_temp_offset | 402B | Temperatursensor Nullpunkt | Temperatursensor Nullpunkt | R/W | Float | 8 |
var_TB82_cal_status | 4085 | Cal Status | R | Enum | 8 | |
var_TB82_temp_cal_unit | 4086 | Temp cal unit | R/W | Enum | 8 | |
Name | ID | Label | Description | Type | Access | Class |