Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pv_units | 4000 | PV eng. unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 8 |
pv_value | 4001 | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 10 |
sensor_upper_range_limit | 4002 | PV USL | Valore limite sensore superiore - Definisce il valore massimo utilizzabile per il valore di campo superiore. | R | Float | 8 |
sensor_lower_range_limit | 4003 | PV LSL | Valore limite sensore superiore - Definisce il valore massimo utilizzabile per il valore di campo superiore. | R | Float | 8 |
sensor_minimum_span | 4004 | PV Min span | Valore intervallo minimo - Definisce la differenza più piccola consentita tra il valore di campo superiore e il valore di campo inferiore. | R | Float | 8 |
pv_damping_value | 4005 | PV Damp | Valore di smorzamento - Costante di tempo di smorzamento applicata sia alla rappresentazione del valore digitale che al valore analogico della rispettiva uscita analogica. Le unità di questa variabile sono sempre in secondi. | R/W | Float | 8 |
analog_value | 4006 | AO | Valore uscita analogica - Valore che traccia la rappresentazione del valore digitale, sotto le modalità operative normali | R/W | Float | 66 |
fail_mode | 4007 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
percent_range | 4008 | PV % rnge | Percentuale di campo - Variabile che traccia la rappresentazione del valore digitale rispetto al campo definito dal valore di campo inferiore e dal valore di campo superiore, per le modalità operative normali. Le unità di questa variabile sono sempre in percentuale. | R | Float | 34 |
transfer_function | 1F84 | Xfer fnctn | Funzione trasferimento - Definisce la funzione di trasformazione che sarà applicata dalla variabile del dispositivo di campo all’uscita analogica e al campo percentuale. La funzione di trasferimento non influisce sulla rappresentazione del valore digitale. | R | Enum | 32 |
pv_upper_range_value | 4009 | PV URV | Valore di campo superiore - Definisce il punto finale operativo da cui deriva il valore analogico e il punto 100% del campo percentuale. Inoltre, il valore di campo superiore definisce un punto finale operativo da cui derivano gli allarmi associati al valore analogico e gli allarmi associati alla rappresentazione del valore digitale. | R/W | Float | 32 |
pv_lower_range_value | 400A | PV LRV | Valore di campo inferiore - Definisce il punto finale operativo da cui si ricava il valore analogico e il punto 0% del campo percentuale. Inoltre, il valore di campo inferiore definisce un punto finale operativo da cui derivano gli allarmi associati al valore analogico e gli allarmi associati alla rappresentazione del valore digitale. | R/W | Float | 32 |
sensor_serial_number | 400B | PV Snsr s/n | Numero di serie sensore - Identifica in modo univoco il sensore da cui deriva principalmente la rappresentazione del valore digitale o la variabile dispositivo di campo. | R/W | Unsigned | 2048 |
temp_unit | 400C | Temp Unit | R | Enum | 8 | |
temp_value | 400D | Temp | Temperature- In Auto temp comp mode, it is the Temp read with the temp sensor. In Manual temp comp mode, it is the user entered temp value | R | Float | 10 |
ref_impedance_unit | 400E | Ref Impedance unit | R | Enum | 8 | |
ref_impedance_value | 400F | Ref. Impedance | Reference Impedance | R | Float | 10 |
input_mv_unit | 4010 | Input unit | R | Enum | 8 | |
input_mv_value | 4011 | Input | Input mV - Millivolt input value. | R | Float | 10 |
PV_efficiency | 4024 | PV efficiency | PV sensor efficiency (slope) value in percent | R/W | Float | 8 |
PV_offset | 4025 | PV offset | PV sensor offset value. | R/W | Float | 8 |
temp_slope | 4026 | Temperature sensor Slope | Temperature sensor Slope | R/W | Float | 8 |
temp_offset | 4027 | Temperature sensor offset | Temperature sensor offset value. | R/W | Float | 8 |
temp_cal_2pt | 401C | 2 Point Cal Temp. value | Temperature value for 2 point PV calib | W | Float | 8 |
PV_cal_low_value | 4018 | PV cal low value | PV low value for 2 point calibration. | W | Float | 8 |
PV_cal_high_value | 4019 | PV cal high value | PV high value for 2 point calibration. | W | Float | 8 |
one_point_PV_value | 402D | PV value for one point cal | R/W | Float | 8 | |
temp_cal_value | 401B | Temp. calibration value | Temperature calibration value | W | Float | 8 |
temp_comp | 4016 | Temp comp type | Temperature compensation type | R/W | Enum | 8 |
manual_temp_unit | 401E | Manual temp units | R/W | Enum | 8 | |
manual_temp_comp_value | 4017 | Manual Temp. | Manual Temperature Compensation Value - is used in Nernstian temp. comp. when the Temp Comp selection is Manual | R/W | Float | 8 |
units_code | 07E9 | R/W | Enum | 4096 | ||
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
write_protect_code | 07EE | R/W | Enum | 4096 | ||
company_identification_code | 07EF | R/W | Enum | 4096 | ||
response_code | 0096 | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. | R/W | Enum | 129 | |
comm_status | 0098 | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R/W | BitEnum | 131 | |
device_status | 0097 | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R/W | BitEnum | 131 | |
manufacturer_id | 0099 | Produttore | Codice identificazione produttore - Si riferisce ad un produttore specifico, solitamente il nome di una società, che è responsabile della produzione del dispositivo di campo. | R | Enum | 128 |
device_type | 009A | Model | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer | R | Enum | 128 |
request_preambles | 009B | Num req preams | Number of Request Preambles- Number of Preambles required from the Host request by the Field Device | R | Unsigned | 128 |
universal_revision | 009C | Universal rev | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to | R | Unsigned | 128 |
transmitter_revision | 009D | Fld dev rev | Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to | R | Unsigned | 128 |
software_revision | 009E | Software rev | Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device | R | Unsigned | 2048 |
hardware_revision | 009F | Hardware rev | Versione hardware - Versione che corrisponde all’hardware dell’elettronica del dispositivo di campo. | R | Unsigned | 2048 |
physical_signaling_code | 00AB | Physicl signl code | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port | R | Enum | 2048 |
device_flags | 00A0 | Dev flags | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer | R | BitEnum | 128 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 128 |
polling_address | 00A2 | Poll addr | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) | W | Unsigned | 128 |
Name | ID | Label | Description | Type | Access | Class |