Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
var_TB82_user_defined_conc_x5 | 401D | x5 Cond | x5 Conductivity point of the user defined concentration curve. | R/W | Float | 8 |
var_TB82_user_defined_conc_x6 | 401F | x6 Cond | x6 Conductivity point of the user defined concentration curve. | R/W | Float | 8 |
var_TB82_user_defined_conc_y1 | 4016 | y1 Concen | y1 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y2 | 4018 | y2 Concen | y2 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y3 | 401A | y3 Concen | y3 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y4 | 401C | y4 Concen | y4 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y5 | 401E | y5 Concen | y5 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y6 | 4020 | y6 Concen | y6 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_lcd_secondary | 402D | LCD secondry disp | The parameter sets the HMI's local LCD secondary display area to one of several options. | R/W | Enum | 256 |
var_TB82_security_lock | 402E | Security Lock | When ENABLED, the Security Password will be active for Security mode on local HMI. If Security Lock is disabled, then the Security mode of operation can be accessed from the local HMI without supplying the password. | R/W | Enum | 2048 |
var_TB82_configuration_lock | 402F | Configuration Lock | When ENABLED, the Security Password will be active for Config mode on local HMI. Config parameters will be write protected on the HART interface. When the Configuration-Lock is DISABLED, the Config mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_calibration_lock | 4030 | Calibration Lock | When ENABLED, the Security Password will be active for Calibrate mode on local HMI. Calib parameters will be write protected on the HART interface. When the Calibration Lock is DISABLED, the Calibrate mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_output_lock | 4031 | Output Lock | When ENABLED, the Security Password will be active for Output mode on local HMI. Output related parameters will be write protected on the HART interface. When the Output Lock is DISABLED, the Output mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_password_digit_1 | 4081 | Secur. Passwrd 1 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_password_digit_2 | 4082 | Secur. Passwrd 2 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_password_digit_3 | 4083 | Secur. Passwrd 3 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_pv_slope_units | 4062 | PV slope units | R/W | Enum | 8 | |
var_TB82_pv_slope | 4029 | PV Slope | PV sensor efficiency (slope) value in percent | R/W | Float | 8 |
var_TB82_pv_offset_units | 4045 | PV snsr offset unit | PV sensor offset unit | R/W | Enum | 8 |
var_TB82_pv_offset | 402A | PV offset | PV sensor offset value. | R/W | Float | 8 |
var_TB82_temp_slope_units | 4065 | Temp slope units | R/W | Enum | 8 | |
var_TB82_temp_slope | 402B | Temp snsr Slope | Temperature sensor Slope | R/W | Float | 8 |
var_TB82_temp_offset_units | 4047 | Temp snsr offset unit | Temperature sensor offset unit | R/W | Enum | 8 |
var_TB82_temp_offset | 402C | Temp snsr offset | Temp snsr offset | R/W | Float | 8 |
var_TB82_cal_status | 4088 | Cal Status | R | Enum | 8 | |
var_TB82_temp_cal_unit | 4089 | Temp cal unit | R/W | Enum | 8 | |
var_TB82_temp_cal_value | 408A | Temp cal value | R/W | Float | 8 | |
var_TB82_one_point_PV_value | 4092 | PV value for PV cal | R/W | Float | 8 | |
var_TB82_pv_cal_unit | 4093 | R/W | Enum | 8 | ||
unique_device_type_code | 07ED | R/W | Enum | 4096 | ||
rosemount_model_code | 07F5 | R/W | Enum | 4096 | ||
rosemount_analytical_model_code | 07F6 | R/W | Enum | 4096 | ||
kayray_model_code | 07F7 | R/W | Enum | 4096 | ||
micro_motion_model_code | 07F8 | R/W | Enum | 4096 | ||
units_code | 07E9 | R/W | Enum | 4096 | ||
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
material_code | 07EC | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
write_protect_code | 07EE | R/W | Enum | 4096 | ||
company_identification_code | 07EF | R/W | Enum | 4096 | ||
burst_mode_control_code | 07F0 | R/W | Enum | 4096 | ||
physical_signaling_codes | 07F1 | R/W | Enum | 4096 | ||
flag_assignment | 07F2 | R/W | Enum | 4096 | ||
operating_mode_code | 07F3 | R/W | Enum | 4096 | ||
analog_output_numbers_code | 07F4 | R/W | Enum | 4096 | ||
response_code | 0096 | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. | R/W | Enum | 129 | |
comm_status | 0098 | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R/W | BitEnum | 131 | |
device_status | 0097 | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R/W | BitEnum | 131 | |
manufacturer_id | 0099 | Manufacturer | Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device. | R | Enum | 128 |
device_type | 009A | Model | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer | R | Enum | 128 |
Name | ID | Label | Description | Type | Access | Class |