Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
var_TB82_user_defined_conc_x5 | 401D | x5 Cond | x5 Conductivity point of the user defined concentration curve. | R/W | Float | 8 |
var_TB82_user_defined_conc_x6 | 401F | x6 Cond | x6 Conductivity point of the user defined concentration curve. | R/W | Float | 8 |
var_TB82_user_defined_conc_y1 | 4016 | y1 Concen | y1 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y2 | 4018 | y2 Concen | y2 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y3 | 401A | y3 Concen | y3 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y4 | 401C | y4 Concen | y4 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y5 | 401E | y5 Concen | y5 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_user_defined_conc_y6 | 4020 | y6 Concen | y6 Concentration point corresponding to x1 Conductivity in the user defined concentration curve | R/W | Float | 8 |
var_TB82_lcd_secondary | 402D | LCD secondry disp | The parameter sets the HMI's local LCD secondary display area to one of several options. | R/W | Enum | 256 |
var_TB82_security_lock | 402E | Security Lock | When ENABLED, the Security Password will be active for Security mode on local HMI. If Security Lock is disabled, then the Security mode of operation can be accessed from the local HMI without supplying the password. | R/W | Enum | 2048 |
var_TB82_configuration_lock | 402F | Configuration Lock | When ENABLED, the Security Password will be active for Config mode on local HMI. Config parameters will be write protected on the HART interface. When the Configuration-Lock is DISABLED, the Config mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_calibration_lock | 4030 | Calibration Lock | When ENABLED, the Security Password will be active for Calibrate mode on local HMI. Calib parameters will be write protected on the HART interface. When the Calibration Lock is DISABLED, the Calibrate mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_output_lock | 4031 | Output Lock | When ENABLED, the Security Password will be active for Output mode on local HMI. Output related parameters will be write protected on the HART interface. When the Output Lock is DISABLED, the Output mode of operation can be accessed from the local HMI without supplying the password | R/W | Enum | 2048 |
var_TB82_password_digit_1 | 4081 | Secur. Passwrd 1 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_password_digit_2 | 4082 | Secur. Passwrd 2 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_password_digit_3 | 4083 | Secur. Passwrd 3 | Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. | R/W | Unsigned | 2048 |
var_TB82_pv_slope_units | 4062 | PV slope units | R/W | Enum | 8 | |
var_TB82_pv_slope | 4029 | PV Slope | PV sensor efficiency (slope) value in percent | R/W | Float | 8 |
var_TB82_pv_offset_units | 4045 | PV snsr offset unit | PV sensor offset unit | R/W | Enum | 8 |
var_TB82_pv_offset | 402A | PV offset | PV sensor offset value. | R/W | Float | 8 |
var_TB82_temp_slope_units | 4065 | Temp slope units | R/W | Enum | 8 | |
var_TB82_temp_slope | 402B | Temp snsr Slope | Temperature sensor Slope | R/W | Float | 8 |
var_TB82_temp_offset_units | 4047 | Temp snsr offset unit | Temperature sensor offset unit | R/W | Enum | 8 |
var_TB82_temp_offset | 402C | Temp snsr offset | Temp snsr offset | R/W | Float | 8 |
var_TB82_cal_status | 4088 | Cal Status | R | Enum | 8 | |
var_TB82_temp_cal_unit | 4089 | Temp cal unit | R/W | Enum | 8 | |
var_TB82_temp_cal_value | 408A | Temp cal value | R/W | Float | 8 | |
var_TB82_one_point_PV_value | 4092 | PV value for PV cal | R/W | Float | 8 | |
var_TB82_pv_cal_unit | 4093 | R/W | Enum | 8 | ||
unique_device_type_code | 07ED | R/W | Enum | 4096 | ||
rosemount_model_code | 07F5 | R/W | Enum | 4096 | ||
rosemount_analytical_model_code | 07F6 | R/W | Enum | 4096 | ||
kayray_model_code | 07F7 | R/W | Enum | 4096 | ||
micro_motion_model_code | 07F8 | R/W | Enum | 4096 | ||
units_code | 07E9 | R/W | Enum | 4096 | ||
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
material_code | 07EC | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
write_protect_code | 07EE | R/W | Enum | 4096 | ||
company_identification_code | 07EF | R/W | Enum | 4096 | ||
burst_mode_control_code | 07F0 | R/W | Enum | 4096 | ||
physical_signaling_codes | 07F1 | R/W | Enum | 4096 | ||
flag_assignment | 07F2 | R/W | Enum | 4096 | ||
operating_mode_code | 07F3 | R/W | Enum | 4096 | ||
analog_output_numbers_code | 07F4 | R/W | Enum | 4096 | ||
response_code | 0096 | O código de resposta específicado comando- O dado que retornado na resposta do dispositivo de campo, que indica o sucesso relativo do comando enviado no pedido do Host Essa informação pode ser relacionada ao dado do pedido do host ou ao comando próprio | R/W | Enum | 129 | |
comm_status | 0098 | Resumo de erros de comunicação – o dispositivo de campo tem detectado a seguinte condição de erro enquanto tenta receber o host exigido. Sendo assim o Comando não foi aceito, e o pedido do Host não foi aceito, e o pedido do host não causou nenhuma alteração para ocorrer no dispositivo de campo. | R/W | BitEnum | 131 | |
device_status | 0097 | Status do dispositivo de campo- O dado indica que o dispositivo de campo detectou condição (s) no dispositivo de campo em relação à: seu hardware / a validade da variável / seu status de operação / um processo interno | R/W | BitEnum | 131 | |
manufacturer_id | 0099 | Fabricante | Código de Identificação do Fabricante- Referencia o fabricante específico, o qual é usualmente o nome da empresa, que é responsável pela produção desse dispositivo de campo. | R | Enum | 128 |
device_type | 009A | Modelo | Modelo- Referência o tipo de dispositivo de campo, usualmente um número de modelo apresentado, que é único para o fabricante único | R | Enum | 128 |
Name | ID | Label | Description | Type | Access | Class |