Name ID Label Description Type Access Class
temperaturePDQ 4054 Temperature Data Quality R Enum 2
temperatureLS 4055 Temperature Limit Status R Enum 2
T_Status 4056 Temperature Status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 0
T_Classification 4057 Temperature Classification R Enum 0
deviceVariableFamilyCodes_Temp 4058 Device family R Enum 0
T_UpperRange_Obj_value_0 4059 Temperature USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
T_LowerRange_Obj_value_0 405A Temperature LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
T_MinimumSpan_Obj_value_0 405B Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
T_DampingTime 405C Damping Damping Value- Damping time constant applied to temperature value. The units of this variable are always in seconds. R/W Float 0
TSim_Enable 405D Simulation Temperature value simulation status. R/W Enum 0
TmainTaskDelayTimeMax 405E Temperature Update Period R Time 0
T_transducerSerialNumber 405F Temperature Sensor Serial Number Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 0
swWriteProtection 4113 SW Write Protection Indicates whether variables can be written to the Field Device, or whether commands that cause actions to be performed in the Field Device, can or cannot occur. R/W Enum 0
mountOrientation 4118 Mounting Orientation Device may be either Top or Bottom Mounted. R/W Enum 0
serviceCodeLogOut 4149 Service Code Logout Service Code Logout W Unsigned 0
T_Offset_Obj_Value_0 40C4 Offset Offsets the temperature value read from the RTD at the bottom of the probe. R/W Float 0
HartClearDiagnosticsHistory 414C W Unsigned 0
totalWorkingTimeHour 414E Total Run Time Total run time in days since last device reset. R Unsigned 2
cpuLoad 414F CPU Load Percent of CPU load. R Float 2
alarm_delay 411A Alarm Delay The output will go to alarm state only if there is a loss of signal that lasts at least the duration of the alarm delay. R/W Float 0
pulseWidth 411B Pulse Width Amount of energy used for the level measurement. R/W Unsigned 0
levelDeviceType 4014 Device Configuration Options include 1 or 2 Levels and with or without Temperature. R/W Enum 0
blanking 406E Blanking Distance Blanking is a measured area which the LMT will be set to ignore including the nozzle distance. It may be necessary to extend the Blanking further past the nozzle to ignore reflections from the top portion of the probe. Blanking is set in terms of units. To adjust the Blanking, enter the distance from the Reference Measurement to be ignored. Do not blank into your measuring range. Signal will be lost. R/W Float 0
readOnlySwitchStatus 4114 Status Hardware switch that allows remote access. R Enum 0
cbSoftwareRevisionChars 4154 Software Revision Electronics software revision. R ASCII 0
Name ID Label Description Type Access Class