Name ID Label Description Type Access Class
temperaturePDQ 4054 Temperature Data Quality R Enum 2
temperatureLS 4055 Temperature Limit Status R Enum 2
T_Status 4056 Temperature Status Estado de familia de dispositivo: Indica información de estado adicional de una variable de dispositivo para una familia de dispositivos específica. R BitEnum 0
T_Classification 4057 Temperature Classification R Enum 0
deviceVariableFamilyCodes_Temp 4058 Device family R Enum 0
T_UpperRange_Obj_value_0 4059 Temperature USL Valor límite superior del sensor: Define el valor máximo utilizable para el valor de rango superior. R Float 0
T_LowerRange_Obj_value_0 405A Temperature LSL Valor límite inferior del sensor: Define el valor mínimo utilizable para el valor de rango inferior. R Float 0
T_MinimumSpan_Obj_value_0 405B Minimum Span Valor de span mínimo: Define la menor diferencia permitida entre el valor de rango superior y el valor de rango inferior. R Float 0
T_DampingTime 405C Damping Damping Value- Damping time constant applied to temperature value. The units of this variable are always in seconds. R/W Float 0
TSim_Enable 405D Simulation Temperature value simulation status. R/W Enum 0
TmainTaskDelayTimeMax 405E Temperature Update Period R Time 0
T_transducerSerialNumber 405F Temperature Sensor Serial Number Número de serie del sensor: Identifica de manera única el sensor del que se deriva principalmente la representación del valor digital o la variable del dispositivo de campo. R Unsigned 0
swWriteProtection 4113 SW Write Protection Indicates whether variables can be written to the Field Device, or whether commands that cause actions to be performed in the Field Device, can or cannot occur. R/W Enum 0
mountOrientation 4118 Mounting Orientation Device may be either Top or Bottom Mounted. R/W Enum 0
serviceCodeLogOut 4149 Service Code Logout Service Code Logout W Unsigned 0
T_Offset_Obj_Value_0 40C4 Offset Offsets the temperature value read from the RTD at the bottom of the probe. R/W Float 0
HartClearDiagnosticsHistory 414C W Unsigned 0
totalWorkingTimeHour 414E Total Run Time Total run time in days since last device reset. R Unsigned 2
cpuLoad 414F CPU Load Percent of CPU load. R Float 2
alarm_delay 411A Alarm Delay The output will go to alarm state only if there is a loss of signal that lasts at least the duration of the alarm delay. R/W Float 0
pulseWidth 411B Pulse Width Amount of energy used for the level measurement. R/W Unsigned 0
levelDeviceType 4014 Device Configuration Options include 1 or 2 Levels and with or without Temperature. R/W Enum 0
blanking 406E Blanking Distance Blanking is a measured area which the LMT will be set to ignore including the nozzle distance. It may be necessary to extend the Blanking further past the nozzle to ignore reflections from the top portion of the probe. Blanking is set in terms of units. To adjust the Blanking, enter the distance from the Reference Measurement to be ignored. Do not blank into your measuring range. Signal will be lost. R/W Float 0
readOnlySwitchStatus 4114 Status Hardware switch that allows remote access. R Enum 0
cbSoftwareRevisionChars 4154 Software Revision Electronics software revision. R ASCII 0
Name ID Label Description Type Access Class