Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
cbHardwareRevisionChars | 4155 | Hardware Revision | Electronics hardware revision. | R | ASCII | 0 |
feSoftwareRevisionChars | 4156 | Software Revision | Sensor software revision. | R | ASCII | 0 |
feHardwareRevisionChars | 4157 | Hardware Revision | Sensor hardware revision. | R | ASCII | 0 |
fpgaVersionHMI | 4158 | FPGA Revision | Field Programmable Gate Array revision. | R | ASCII | 0 |
transducerId | 4159 | Transducer ID | Transducer ID | R | Unsigned | 0 |
Level_ObjSim_value_0 | 415B | Level | Height of product in the vessel. | R/W | Float | 0 |
LinLevel_FlowObjSim_value_0 | 415C | Flow | Linearized flow value | R/W | Float | 0 |
LinLevel_VolumeObjSim_value_0 | 415D | Volume | Linearized volume value | R/W | Float | 0 |
Ullage_ObjSim_value_0 | 415E | Ullage | Ullage Value | R/W | Float | 0 |
Interface_ObjSim_value_0 | 415F | Interface | Interface is the height at which a surface forms a common boundary between two immiscible liquids. | R/W | Float | 0 |
LinInterface_VolumeObjSim_value_0 | 4160 | Volume | Linearized volume value | R/W | Float | 0 |
T_ObjSim_value_0 | 4161 | Temperature | Sensortemperatur- Die Temperatur des Sensors, der die Prozessmessung durchführt | R/W | Float | 0 |
Level_Obj_unit_dummy | 4043 | Level Unit | Engineering Units for the distance measurements. | R/W | Enum | 0 |
LinLevel_FlowObj_unit_dummy | 4162 | Flow Unit | R/W | Enum | 0 | |
LinLevel_VolumeObj_unit_dummy | 4163 | Volume Unit | R/W | Enum | 0 | |
index_array_sim | 416F | index sim | R/W | Index | 4096 | |
Level_Alarm_Enable | 4127 | Alarm | Level Alarm Enable/Disable | R/W | Enum | 0 |
Ullage_Alarm_Enable | 4128 | Alarm | Ullage Alarm Enable/Disable | R/W | Enum | 0 |
Interface_Alarm_Enable | 4129 | Alarm | Interface Alarm Enable/Disable | R/W | Enum | 0 |
T_Alarm_Enable | 412A | Alarm | Temperature Alarm Enable/Disable | R/W | Enum | 0 |
index_array_alarm_enable | 4172 | Index Alarm Enable | R/W | Index | 4096 | |
reverseSignalPolarity | 411D | Signal Polarity | The signal can be either standard or reversed. | R/W | Enum | 0 |
level_threshold | 411C | Threshold | The Threshold voltage provides a method of signal detection along the waveform. The signal from the process reflection must cross this barrier to be detected as a signal. The LMT is designed to detect the first pulse crossing the Threshold. The Threshold may need to be increased to avoid baseline interference or decreased to detect the correct pulse. | R/W | Float | 0 |
alarmSelectionSource | 4178 | Alarm Source | Alarm selection source may be either Software, Hardware Low or Hardware High. | R | Enum | 0 |
spanLimitLowValue | 4120 | Low Saturation | Saturation limit low of the analog output current. | R/W | Float | 0 |