Name ID Label Description Type Access Class
l_k1 404E L k1 K-factor k1 is related to frequency f1. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_k2 404F L k2 K-factor k2 is related to frequency f2. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_k3 4050 L k3 K-factor k3 is related to frequency f3. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_k4 4051 L k4 K-factor k4 is related to frequency f4. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_k5 4052 L k5 K-factor k5 is related to frequency f5. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_f1 4048 L f1 Frequency point liquid f1 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_f2 4049 L f2 Frequency point liquid f2 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_f3 404A L f3 Frequency point liquid f3 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_f4 404B L f4 Frequency point liquid f4 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
l_f5 404C L f5 Frequency point liquid f5 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. R/W Float 2048
Name ID Label Description Type Access Class