Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
l_k1 | 404E | L k1 | K-factor k1 is related to frequency f1. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_k2 | 404F | L k2 | K-factor k2 is related to frequency f2. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_k3 | 4050 | L k3 | K-factor k3 is related to frequency f3. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_k4 | 4051 | L k4 | K-factor k4 is related to frequency f4. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_k5 | 4052 | L k5 | K-factor k5 is related to frequency f5. Please refer to calibration protocol! !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_f1 | 4048 | L f1 | Frequency point liquid f1 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_f2 | 4049 | L f2 | Frequency point liquid f2 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_f3 | 404A | L f3 | Frequency point liquid f3 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_f4 | 404B | L f4 | Frequency point liquid f4 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
l_f5 | 404C | L f5 | Frequency point liquid f5 for k-factor linearisation. !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES. | R/W | Float | 2048 |
Name | ID | Label | Description | Type | Access | Class |