Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pressure_value | 138E | Pres | Field Device Variable Value- Digital value that can change without user intervention. Pressure- Measured proccess pressure in relation to a reference pressure. | R | Float | 10 |
pressure_percent_range | 138F | Pres % rnge | Percent of Range- Variable which represents the digital value with respect to the range defined by the lower range value and upper range value. For normal operating modes. This variable is always in percent. Pressure- Measured process pressure in relation to a reference pressure. | R | Float | 34 |
pressure_upper_range_limit | 1393 | Pres USL | Upper Sensor Limit Value- Defines the maximum value able to be used for the upper range value. Pressure- Measured proccess pressure in relation to a reference pressure. | R/W | Float | 8 |
pressure_lower_range_limit | 1394 | Pres LSL | Lower Sensor Limit Value- Defines the lowest allowable value for the lower range value. Pressure- Pressure of the process with respect to a reference pressure. | R/W | Float | 8 |
pressure_minimum_span | 1390 | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Measured proccess pressure in relation to a reference pressure. | R/W | Float | 8 |
pressure_output_transfer_function | 1391 | Pres xfer fnctn | Funzione trasferimento - Definisce la funzione di trasformazione che sarà applicata dalla variabile del dispositivo di campo all’uscita analogica e al campo percentuale. La funzione di trasferimento non influisce sulla rappresentazione del valore digitale. | R/W | Enum | 32 |
pressure_upper_range_value | 1396 | Pres URV | Upper Range Value- Defines the endpoint for the analog value and the 100% point of the percent range. The upper range value also defines the operational endpoint from which the alarms for the analog output value as well as the associated digital value are taken. Pressure- Measured proccess pressure in relation to a reference pressure. | R/W | Float | 34 |
pressure_lower_range_value | 1397 | Pres LRV | Lower Range Value- Defines the operational endpoint or the analog output signal and 0% of the percent range. In addition, the lower range value defines an operational endpoint from which the alarm values for the analog output as well as the associated digital value are derived. Pressure- Pressure of the process with respect to a reference pressure. | R/W | Float | 34 |
pressure_damping_value | 1398 | Pres damp | Damping Value- Damping time which affects both the digital and analog output values. The variable is always in seconds. Pressure- Pressure of the process with respect to a reference pressure. | R/W | Float | 10 |
flange_type | 139A | Flange type | Flange Type- Part next to the sensor which physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 2048 |
Name | ID | Label | Description | Type | Access | Class |