Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
descriptor | 00A5 | Descriptor | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. | R/W | PackedAscii | 2048 |
date | 00A6 | Fecha | Fecha: Fecha del calendario gregoriano almacenada en el dispositivo de campo. El usuario puede usar esta fecha de cualquier manera. No hay ningún uso específico recomendado. | R/W | HartDate | 2048 |
write_protect | 00A7 | Write protect | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. | R | Enum | 2050 |
private_label_distributor | 00A8 | Distribuidor | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers | R | Enum | 2048 |
final_assembly_number | 00A9 | Final asmbly num | Número de ensamblaje final: Número que se utiliza con fines de identificación y está asociado al dispositivo de campo en general. | R/W | Unsigned | 2048 |
eeprom_select | 0FAB | Selección EEPROM | Selección de memoria de solo lectura borrable eléctricamente: Controla los datos de: Memoria EEPROM de solo lectura/Memoria de solo lectura. | R/W | Enum | 4096 |
response_preambles | 0FE2 | Num resp preams | Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host | W | Unsigned | 128 |
burst_command_number | 0FFD | Burst option | Opción de ráfaga: Selecciona las variables a las que se aplicarán ráfagas si el modo de ráfaga está activado. | W | Enum | 128 |
burst_mode_select | 0FFF | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | W | Enum | 128 |
pressure_units | 138D | Pressure unit | Field Device Variable Unit- unit in which digital value, minimum span, upper range value, lower range value, lower sensor limit, upper sensor limit, lower sensor trim point and upper sensor trim point are displayed. Pressure- Measured process pressure in relation to a reference pressure. | R/W | Enum | 8 |
Name | ID | Label | Description | Type | Access | Class |