Loading…
Name ID Label Description Type Access Class
xmtr_specific_status_1 0FB6 Error register 2 Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
xmtr_specific_status_2 0FB7 Error register 3 Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
transmitter_variable_code_1 0FA0 Index into Dynamic Variables Array- Is the first an array of addresses, whose value is identified by the Field Device Variable Code R/W Index 4096
transmitter_variable_code_2 0FA2 Index into Dynamic Variables Array- Is the second of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 4096
transmitter_variable_code_3 0FA3 Index into Dynamic Variables Array- Is the third of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 4096
transmitter_variable_code_4 0FA4 Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 4096
flow_units 1F7B Range unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
flow_value 1F7C PV Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R/W Float 34
flow_analog_value 1F7D AO1 Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
flow_percent_range 1F7E PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R/W Float 34
Name ID Label Description Type Access Class