Name ID Label Description Type Access Class
unit_sec 4066 R/W Enum 32
unit_density 4067 R/W Enum 32
unit_hz 4069 R/W Enum 32
unit_ma 406B R/W Enum 32
unit_liter 406D R/W Enum 32
unit_percent 406F R/W Enum 32
unit_none 4072 R/W Enum 32
unit_special 4073 R/W Enum 32
language 4031 Language Help Language R/W Enum 2048
meter_size 4011 Meter size Help meter size R/W Enum 2048
filter 4023 Filter Help Filter R/W Enum 2048
prog_unit 4038 Prog unit select the programable unit as mass flow or not R/W Enum 2048
function_p1p2 402B Function P7/G2 Select the function for P7/G2 R/W Enum 2048
function_x1 4024 Function X1/G2 Select the function for X1/G2 R/W Enum 2048
Iout_at_alarm 402E Iout at Alarm High or low Iout at Alarm R/W Enum 2048
detector_e_pipe 4013 Detector e.pipe switch on or off the detector empty pipe R/W Enum 2048
alarm_e_pipe 4014 Alarm empty pipe switch on or off the alarm at empty pipe R/W Enum 2048
Iout_at_e_pipe 4015 Iout at empty pipe High or low Iout at alarm empty pipe R/W Enum 2048
simulation 4062 Simulation Switch on or off simulation mode for flow R/W Enum 2048
test_mode 4063 Test mode Switch on or off testing mode Cs and Cz R/W Enum 2048
totalizer_function 4018 Totalizer funct. totalizer function can be in standard mode with totalizers forward and reverse or in differential mode with only one totalizer R/W Enum 2048
display_1st_line 4032 1st line Select the value to display at the 1st line R/W Enum 2048
display_2nd_line 4033 2nd line Select the value to display at the 2nd line R/W Enum 2048
display_1st_line_multipl 4034 1st line multipl. Select the value to display in multiplex mode at the 1st line R/W Enum 2048
display_2nd_line_multipl 4035 2nd line multipl. Select the value to display in multiplex mode at the 2nd line R/W Enum 2048
operating_mode 4025 Operating mode Select the operating mode R/W Enum 2048
flowdirection 4026 Flowdirection flowdirection can be in forward/reverse or in forward only mode R/W Enum 2048
flowindication 4027 Flowindication Flowindication can be changed from standard to opposite direction R/W Enum 2048
module 405F Module Help module R/W Enum 2048
range_velocity 4055 Range velocity Help range velocity R/W Enum 2048
range_05_DN 4056 range<.05rangeDN Help range < .05 rangeDN R/W Enum 2048
range_fixed 4057 range DN R/W Enum 2048
debit_excitation 4053 Debit excitation Help debit excitation R/W Enum 2048
excitation 4054 Excitation Help excitation R Enum 2048
analog_range 4058 Analog range Help analog range R/W Enum 2048
preamplifier 4049 Preamplifier Help preamplifier R/W Enum 2048
unsigned_char_variable_code 4093 Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input R/W Index 4096
max_alarm 402C MAX alarm Help MAX alarm R/W Unsigned 2048
min_alarm 402D MIN alarm Help MIN alarm R/W Unsigned 2048
instr_address 4065 Instr. address Help instr. address R/W Unsigned 2048
overflow_f 4001 Overflow >F Help overflow >F R Unsigned 18
overflow_r 4002 Overflow Help overflow R Unsigned 18
mains_interrupt 401B Mains interrupt Help mains interrupt R/W Unsigned 18
kodenummer 4060 Code number code number to access service parameters R/W Unsigned 2048
instr_number 405E Instr. number Help instument number R/W Unsigned 2048
calibration_mode 4048 Calibration mode Help calibration mode R/W Unsigned 2048
int_variable_code 40A0 Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input R/W Index 4096
pulse_factor 4000 Pulse factor Help pulse factor R/W Float 2048
pulse_width 4020 Pulse width Help pulse width R/W Float 2048
low_flow_cut_off 400F Low flow cutoff Help low flow cutoff R/W Float 2048
Name ID Label Description Type Access Class